PROBLEMS

 

 

 

 

 

 

 

 

 

 

PROBLEM

 

 

POSSIBLE CAUSE

 

 

WHAT TO DO

 

 

 

 

 

 

 

 

 

 

 

18. Dual Procedure is not

 

 

a. Gun has not been selected at the

 

 

a. Set dual procedure switch at control

 

 

functioning when using the

 

 

control box.

 

 

box to the gun position. Refer to

 

 

remote dual procedure switch.

 

 

 

 

 

operating instructions.

 

 

 

 

 

b. Faulty Remote Dual Procedure

 

 

b. Remove switch. Check continuity

 

 

 

 

 

Switch.

 

 

between switch pins with switch closed

 

 

 

 

 

 

 

 

and no continuity with switch open. If it

 

 

 

 

 

 

 

 

fails a continuity test, repair or replace

 

 

 

 

 

 

 

 

switch.

 

 

 

 

 

c. Faulty Local Dual Procedure

 

 

c. Refer to Problem 19, Local Dual

 

 

 

 

 

Switch.

 

 

Procedure Switch.

 

 

 

 

 

d. Defective Control Box to Wire

 

 

d. With switch installed disconnect J2 plug

 

 

 

 

 

Feed Unit cable, associated

 

 

from control board. Check continuity

 

 

 

 

 

harness wiring, or control board.

 

 

between P2 pins 4 and 6 with the

 

 

 

 

 

 

 

 

remote switch closed, and no continuity

 

 

 

 

 

 

 

 

with the remote switch open. If a

 

 

 

 

 

 

 

 

continuity test fails, replace or repair the

 

 

 

 

 

 

 

 

damaged harness or cable. Otherwise

 

 

 

 

 

 

 

 

replace control board. (See procedure

 

 

 

 

 

 

 

 

for replacing PC boards).

 

 

 

 

 

e. Problems with serial

 

 

e. Make sure input cable connections are

 

 

 

 

 

communications.

 

 

tight. Make sure parameters on Power

 

 

 

 

 

 

 

 

Source display, such as WFS match

 

 

 

 

 

 

 

 

those on wire feeder display, if not, try

 

 

 

 

 

 

 

 

changing Synergic 7F control board. If

 

 

 

 

 

 

 

 

problem persists, refer to Power Source

 

 

 

 

 

 

 

 

Troubleshooting information. (See

 

 

 

 

 

 

 

 

procedure for replacing PC boards).

 

 

 

 

 

 

 

 

 

 

 

19. Dual Procedure is not

 

 

a. Faulty Local Dual Procedure

 

 

a. Disconnect harness plug from J2 on the

 

 

functioning when using the

 

 

Switch or control board.

 

 

control board. Check that there is

 

 

local dual procedure switch.

 

 

 

 

 

continuity between plug pins 7 and 11

 

 

 

 

 

 

 

 

when local DPS is in position “A” but not

 

 

 

 

 

 

 

 

when in “Gun” or “B”. Now check that

 

 

 

 

 

 

 

 

there is continuity between plug pins 11

 

 

 

 

 

 

 

 

and 12 when local DPS is in position “B”

 

 

 

 

 

 

 

 

but not when in “Gun” or “A”. If any of

 

 

 

 

 

 

 

 

these continuity tests fail repair or replace

 

 

 

 

 

 

 

 

switch or switch harness to correct the

 

 

 

 

 

 

 

 

problem, Otherwise, replace control

 

 

 

 

 

 

 

 

board. (See procedure for replacing PC

 

 

 

 

 

 

 

 

boards).

 

 

 

 

 

e. Problems with serial

 

 

b. Make sure input cable connections are

 

 

 

 

 

communications.

 

 

tight. Make sure parameters on Power

 

 

 

 

 

 

 

 

Source display, such as WFS match those

 

 

 

 

 

 

 

 

on wire feeder display, if not, try changing

 

 

 

 

 

 

 

 

Synergic 7F control board. If problem

 

 

 

 

 

 

 

 

persists, refer to Power Source

 

 

 

 

 

 

 

 

Troubleshooting information. (See

 

 

 

 

 

 

 

 

procedure for replacing PC boards).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 