Gun Cable Connections: Wire Feeder to Gun
a.Check that the drive rolls, feeder guide tubes and gun connector guide tube are appropriate for the electrode size being used. If necessary, change them per section on Wire Feed Drive Roll and Guide Tube Kits.
b.Connect gun to gun connector making sure all pins and gas tube line up with appropriate holes in connector. Tighten gun by turning large nut on gun clockwise.
Synergic 7F Water Connections (for Water-Cooled Guns)
The Synergic 7F models must have a
1)Using hose clamps provided with the
2)In the event the water line fittings on your
GMAW Shielding Gas
WARNING
CYLINDER may explode if damaged.
• Keep cylinder upright and chained to
support.
• Keep cylinder away from areas where it may be damaged.
•Never lift welder with cylinder attached.
•Never allow welding electrode to touch cylinder.
•Keep cylinder away from welding or other live electrical circuits.
BUILDUP OF SHIELDING GAS may harm health or kill.
• Shut off shielding gas supply when not in use.
SEE AMERICAN NATIONAL STANDARD
Customer must provide a cylinder of shielding gas, a pressure regulator, a flow control valve, and a hose from the flow valve to the gas inlet fitting of the Synergic 7F Wire Feed Unit.
Connect a supply hose from the gas cylinder flow valve outlet to the
Gas Guard Regulator - The Gas Guard Regulator is an optional accessory
Install the
95 MAR | – 16 – |