OPTIONAL FEATURES

DRIVE ROLL AND GUIDE TUBE KITS:

Steel Wire Sizes:

4-Roll

*

.068 - 3/32” (1.7 - 2.4mm) Cored

KP655-3/32

*

1/16” (1.6mm) Cored or Solid

KP655-1/16

 

.045 - .052” (1.2 - 1.4mm) Solid

KP655-052S

 

.045 - .052” (1.2 - 1.4mm) Cored

KP655-052C

 

.035” (0.9-1.0mm) Cored

KP655-035C

 

.035” (0.9-1.0mm) Solid

KP655-035S

 

.030” (0.8mm) Solid

KP655-030S

 

.023” (0.6mm) Solid

KP655-025S

Aluminum Wire Sizes:

 

 

1/16” (1.6mm)

KP656-1/16A

 

 

KP647-1/16A**

 

3/64” (1.2mm)

KP656-3/64A

 

 

KP647-3/64A**

 

.040” (1.0mm)

KP647-040A**

 

.035” (0.9mm)

KP656-035A

Drive rolls for only cored electrode sizes are stencilled with a “C” suffix to the wire sizes.

Drive rolls for only solid electrode sizes are stencilled with an “S” suffix to the wire sizes.

Drive rolls for aluminum wire sizes are stencilled with an “A” suffix to the wire sizes.

* Not for Synergic 7H model.

**For use with Binzel European guns. Installation instructions are included with these kits.

INPUT CABLE ASSEMBLIES:

K649 - (Used with Power Wave 450/500) Consists of an 8- conductor control cable with 14-pin control cable plug and a 4/0 (107 mm2) electrode cable with Twist-Mate™ connector. It is rated at 500 amps, 60% duty cycle and is available in lengths of 7 ft. (2 m), 17 ft (5 m), 25 ft (7.6 m), 33 ft (10 m), and 50 ft (15 m).

K648 - (Used with Power Wave 450) Consists of an 8- conductor control cable with a 14-pin plug and a 4/0 (107 mm2) electrode cable with stud terminal. It is rated at 500 amps, 60% duty cycle and is available in lengths of 7 ft (2 m), 17 ft (5 m), 25 ft (7.6 m), 33 ft (10 m) and 50 ft (15 m).

K651 - (Used with Power Wave 350) Consists of an 8- conductor control cable with 14-pin control cable plug and a 2/0 (67 mm2) electrode cable with Twist-Mate™ connector. It is rated at 350 amps, 60% duty cycle and is available in lengths of 7 ft. (2 m), 17 ft (5 m), 33 ft (10 m), and 50 ft (15 m).

K642 - (Control Cable only) Consists of an 8-conductor control cable with 14-pin control cable plug, without electrode cable, and is available in lengths of 7 ft (2 m), 17 ft (5 m), 25 ft (7.6 m), 33 ft (10 m) and 50 ft (15 m).

K643 (Control Cable Extension) Consists of an 8-conductor control cable with 14-pin connectors on each end for extending the control cable between the power source and the control cable. Available in lengths of 17 ft (5m), 25 ft (7.6m), 33 ft (10m), and 50 ft (15m).

WIRE REEL ASSEMBLY:

K299 - Wire reel assembly for customer mounting. Includes 50 - 60 lb wire reel spindle shaft, adjustable brake, insulation and mounting hardware.

READI-REEL ADAPTERS:

K363P - Adapts Lincoln Readi-Reel coils of electrode 30 lb (14 kg) and 22 lb (10 kg) to a 2” (51mm) spindle. Durable molded plastic one piece construction. Designed for easy loading; adapter remains on spindle for quick changeover. (used with K162H)

K438 - Adapts Lincoln Readi-Reel coils of electrode 50-60 lb (22.7-27.2 kg) to a 2” (51mm) spindle. (used with K162H).

SPINDLE ADAPTERS:

K162H - Spindle for mounting Readi-Reels and 2” (51mm) I.D. spools with 60 lb (27.2 kg) capacity. The shaft for the standard wire coils is removed from the mounting frame- work and the K162H is installed in its place. Includes an easily adjustable friction brake for control of overrun.

When used with Readi-Reels a Readi-Reel adapter is required.

K435 - Permits 14 lb (6 kg) Innershield coils to be mounted on 2” (51mm) O.D. spindles. For use with optional K162H adapter.

K468 - Permits 8” (203mm) O.D. spools to be mounted on 2” (51mm) O.D. spindles. For use with optional K162H adapter.

GUN AND CABLE ASSEMBLIES:

The following Lincoln gun and cable assemblies are compatible with both the Synergic 7F and Synergic 7FH Wire Feed units:

K126 - Innershield® gun and cable assemblies are rated at 350 amps, 60% duty cycle. Maximum wire size for Synergic 7F models is 5/64” (2.0 mm). Not recommended for Synergic 7FH models. (Consult sales specifications for appropriate models).

K115 - Innershield gun and cable assemblies are rated at 450 amps, 60% duty cycle. Maximum wire size for Synergic 7F models is 5/64” (2.0 mm). Not recommended for Synergic 7FH models. (Consult sales specifications for appropriate models).

K470 - Magnum 300 GMAW gun and cable assemblies are rated for 300 amps, 60% duty cycle. (Consult sales specifications for appropriate models).

K471 - Magnum 400 GMAW gun and cable assemblies are rated for 400 amps, 60% duty cycle. (Consult sales specifications for appropriate models).

K497 - Magnum 200 GMAW gun and cable assemblies are rated 200 amps, 60% duty cycle . (Consult sales specifications for appropriate models).