Electrical Installation

WARNING

ELECTRIC SHOCK can kill.

Do not touch electrically live parts such as output terminals or internal wiring.

When inching with gun trigger, electrode and drive mechanism are “hot” to work and ground.

Turn OFF welding power source before installing or changing drive roll and/or guide tubes.

Welding power source must be connected to system ground per the National Electrical Code or any applicable local codes.

Only qualified personnel should perform this installation.

Observe all additional Safety Guidelines detailed throughout this manual.

Input Cable: Synergic 7F Control to Power Wave Synergic Type Power Sources

K648 - (Used with Power Wave 450) Consists of an 8- conductor control cable with a 14-pin plug and a 4/0 (107 mm2) electrode cable with stud terminal. It is rated at 500 amps, 60% duty cycle and is available in lengths of 7 ft (2 m), 17 ft (5 m), 25 ft (7.6 m), 33 ft (10 m) and 50 ft (15 m).

K649 - (Used with Power Wave 450/500) Consists of an 8- conductor control cable with a 14-pin control cable plug and a 4/0 (107mm2) electrode cable with Twist-Mate™ connector. It is rated at 500 amps, 60% duty cycle and is available in lengths of 7 ft (2 m), 17 ft (5 m), 25 ft (7.6 m), 33 ft (10 m) and 50 ft (15 m).

K642 (Control Cable Only) - Consists of an 8 conductor control cable with a 14-pin control cable plug, without electrode cable, and is available in lengths of 7 ft (2 m), 17 ft (5 m), 25 ft (7.6 m), 33 ft (10 m) and 50 ft (15 m).

K643 (Control Cable Extension) - Consists of an 8 conductor control cable with 14-pin connectors on each end for extending the control cable between the power source and the control cables. Available in lengths of 17 ft (5 m), 25 ft (8 m), 33 ft (10 m) and 50 ft (15 m).

With input power disconnected from the power source, install the input cable per connection diagram M17770 in the rear of this manual and follow exactly the instructions on the diagram or perform the following:

1)Connect the end of the control cable with the 14- pin cable plug to the mating receptacle on the power source.

2)Connect the electrode lead of that same cable end to the power source output terminal of the desired polarity.

3)Connect the 14-socket plug of the control cable to the mating receptacle on the bottom of the control box.

4)If not using a single continuous electrode cable from the Power Source to Wire Feed Unit, bolt the electrode lead from the power source to the electrode lead to the wire feed unit using the nut and bolt supplied with the K680 Control to Feed Unit cable assembly.

Work Cable

Connect a work lead of sufficient size and length (per the following table) between the proper output terminal on the power source and the work. Be sure the connection to the work makes tight metal-to-metal electrical contact.

 

Current

 

 

 

 

 

 

Copper Work Cable Size, AWG *

 

 

60% Duty

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cycle

 

 

Up to 100 ft Length (30m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

300 Amps

 

00 (67 mm2)

 

 

 

 

 

 

 

 

400 Amps

 

 

 

000 (85 mm2)

 

 

 

500 Amps

 

 

 

000 (85 mm2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*For pulse welding applications, the next larger cable size is recommended.