Napco Security Technologies GEM-P3200 Keypad Configuration Mode, Keypad Beep ON, Entry Sounder ON

Models: GEM-P3200

1 68
Download 68 pages 33.66 Kb
Page 55
Image 55
KEYPAD CONFIGURATION MODE

WI818G 10/05

KEYPAD CONFIGURATION MODE

Page 55

GEMINI

#OF ZONES IN AREA 1 ENTER # ZONES XX

US

 

 

DSTAT

 

ARME

NEXT/YES

A123

E

 

 

D F

B 456

PRIOR/NO

AREA

C7890G

COMPUTERIZED SECURITY SYSTEM

This section will focus on configuring the GEM-RP1CAe2/GEM-K1CA Keypads. If there is more than one keypad in the system, only Keypad No. 1 may be used for programming.

KEYPAD INSTALLATION

Two types of keypads may be used with the GEM-P3200: the GEM-RP1CAe2/GEM-K1CA. Each must be assigned an address number (1–7) and each requires its own configuration procedure (see CONFIGURING THE KEYPADS, which follows, and DIRECT ADDRESS KEYPAD AREA OPTIONS). At least 1 keypad must be used; only 1 is required for a single-area Commercial Burglary installation.

GEM-RP1CAe2/GEM-K1CA- is a 2-line combination fire/burglary/access keypad capable of supporting 4 EZM zones and a PGM output. The GEM-RP1CAe2 or GEM-K1CA is recommended for use as Keypad #1. See "Important Note" on page 2 for more information regarding the various buttons on the GEM-RP1CAe2/GEM-K1CA keypads.

CONFIGURING THE KEYPADS

A total of up to 7 keypads may be connected to the panel.

Configuring the GEM-RP1CAe2/GEM-K1CA Keypad

Each GEM-RP1CAe2/GEM-K1CA keypad must be configured for (a) keypad tactile beep; (b) entry sounder; (c) keypad address; (d) compatibility number; (e) EZM address; and (f) zone response.

To enter the Keypad Configuration Mode:

 

1.

Move jumper JP1 (located in the center of the control panel board) from Pins 1-2 (top two) to Pins 2-3 (bottom

NORMAL

 

two). NOTE: See Wiring Diagram on page 68.

2.

After about 15 seconds, the display will read “XX OUT OF SYSTEM”, where XX indicates the keypad address.

KEYPAD

3.

Press 11123Rand proceed as follows. (Repeat the following procedure for

CONFIGURE

all keypads).

Keypad Beep

ON

Keypad Tactile Beep

Upon entering the Keypad Configuration Mode, “KEYPAD BEEP ON” will be displayed, indicating that the tactile beep, which sounds when any button is pressed, is on.

To turn off the tactile beep, press the Ubutton (the Ubutton will toggle the tac- tile beep on and off). Press Rto continue or press Cto exit.

Entry Sounder

ON

Entry Sounder

To turn off the keypad entry sounder during entry time, press U(the Ubutton will toggle the entry sounder on and off). Press Rto continue or press Cto exit.

Keypad Address

01

Keypad Address

If more than one keypad is installed, each must be assigned a unique keypad address (that is, no two keypads may be numbered alike):

Keypads must be numbered consecutively (missing numbers are not permitted)

Only Keypad No. 1 may be used for programming.

To assign the keypad number, proceed as follows:

1.Enter the assigned keypad number 01–07, then press Uto save. A valid

number will be acknowledged by a short beep; an invalid number will be re- jected by a long beep.

2.Press Rto continue or press Cto exit.

LNAPCO Security Systems

XGEM-P3200 Programming Instructions

Page 55
Image 55
Napco Security Technologies GEM-P3200 Keypad Configuration Mode, Keypad Beep ON, Entry Sounder ON, Keypad Address