Napco Security Technologies GEM-P3200 Alarm/Trouble Reporting Codes Address, System Options, 2422

Models: GEM-P3200

1 68
Download 68 pages 33.66 Kb
Page 35
Image 35
2422

WI818G 10/05

 

 

 

 

 

Page 35

 

 

SYSTEM OPTIONS (ADDRESS 2420 - 2422, 3874, 3905, 3880 -3881)

 

 

 

 

 

 

 

 

 

 

 

 

2420

System Options

 

2421

System Options

 

 

Default

 

 

Option

 

Default

 

 

Option

 

 

OFF

 

1

Disable System Trouble Audible (at Keypad)

 

OFF

 

1

Automatic Interior Bypass/Easy Exit

 

 

OFF

 

2

Chime on Lug E4

 

OFF

 

2

Veri-phone Zones trip Aux. Output

 

 

OFF

 

3

Disable Code required for Func. Mode Lvl. 1

 

OFF

 

3

Veri-phone Zones Priority over Alarms

 

 

OFF

 

4

Disable Code required for EZ Bypass

 

OFF

 

4

AuxOut Chirp on Keyfob Arm/Disarm**

 

 

OFF

 

5

Disable Keypad Instant Button

 

OFF

 

5

Disable Auxout Clear on Disarm

 

 

OFF

 

6

Enable Telephone Line-Fault Test

 

OFF

 

6

2nd Call Answering Machine Override

 

 

OFF

 

7

Disable AC Fail Detection

 

OFF

 

7

Disable Zone Fault Scrolling (Auto Status)

 

 

OFF

 

8

Telco Fail only when Armed

 

OFF

 

8

Veri-phone Zones trip Fire Output

 

 

 

 

 

† NOTE: Not for UL Installations.

 

 

 

 

 

 

**Default for this address contingent on EZ Menu selections.

2422

System Options

Default

 

 

Option

 

 

 

 

ON

 

1

Pulse Burg Output Cadence§

OFF

 

2

Wireless Smoke Low Battery Resound

OFF

 

3

Supervised Alarm Output

OFF

 

4

Enable Smoke Detector Dirty Trouble

OFF

 

5

Disable Area Entry Relays

OFF

 

6

Disable Exit/Entry Urgency Tone at Keypad

OFF

 

7

Select Bell Output on Keyfob Arming

OFF

 

8

Enable Burg. Output on Telco Fail only when Armed

§In Zone Options, Fire Zones, and only Fire Zones, must be programmed for pulse alarm output.

SYSTEM OPTIONS:

1.Select the desired option entering the option number (1-8) for each digit.

2.Enter corresponding option number in address location.

NOTE: Dark shaded data value box shows option not available. Press Uor Dto save.

 

3874

System Options

 

 

Default

 

 

Option

 

 

 

 

 

 

 

 

OFF

 

1

Enable GEM-PRINT

 

 

OFF

 

2

Enable Cancel Report to Telco 3

 

 

OFF

 

3

Wireless Trouble to Telco 1

 

 

OFF

 

4

Wireless Trouble to Telco 3

 

 

OFF

 

5

Enable Set Time/Date Message

SYSTEM

 

OFF

 

6

RESERVED

 

 

 

 

ON

 

7

Enable Keypad Time/Date Display

 

 

 

 

8

RESERVED

 

 

 

 

 

 

OPTIONS

 

3905

System Options

 

 

 

Default

 

 

Option

 

 

 

 

 

 

 

 

OFF

 

1

RESERVED

 

 

OFF

 

2

Enable Exit Delay Restart (SIA-FAR)**

 

 

OFF

 

3

Enable Bell on Exit Error**

 

 

OFF

 

4

Enable Report Exit Err/Recent Close**

 

 

OFF

 

5

Digital Dialer Rpt Enter/Exit Test Mode**

 

 

OFF

 

6

Enable CP-01 Limits**

 

 

OFF

 

7

Disable Call Waiting on First Attempt

 

 

OFF

 

8

Enable Ambush in User Assignment Code Type

 

**Default for this addresses contingent on EZ Menu selections.

ALARM/TROUBLE REPORTING CODES (ADDRESS 3880 - 3881)

ALARM/TROUBLE

ADDRESS 3880-3881

REPORTING CODES

 

 

 

 

 

Wireless Supervisory

3880

 

 

 

 

Wireless Tamper

3881

 

[Default = blank (•) from address 3880-3881]

ALARM/TROUBLE REPORTING CODES:

1.Enter in corresponding address location (left and right digits).

NOTE: Left digit is the first digit and right digit is the second digit in a two digit CS receiver format.

2.Valid entries are: 1-9, 0 and B-F.

NOTE: A is not permitted.

3.To disable a code leave boxes blank (•).

4.Press Uor Dto save.

LNAPCO Security Systems

XGEM-P3200 Programming Instructions

Page 35
Image 35
Napco Security Technologies GEM-P3200 quick start Alarm/Trouble Reporting Codes Address, System Options, 2422, 3874, 3905