WI818G 10/05 |
|
|
|
|
| Page 35 | ||||
|
| SYSTEM OPTIONS (ADDRESS 2420 - 2422, 3874, 3905, 3880 | ||||||||
|
|
|
|
|
|
|
|
|
|
|
| 2420 | System Options |
| 2421 | System Options |
| ||||
| Default |
|
| Option |
| Default |
|
| Option |
|
| OFF |
| 1 | Disable System Trouble Audible (at Keypad) † |
| OFF |
| 1 | Automatic Interior Bypass/Easy Exit |
|
| OFF |
| 2 | Chime on Lug E4 |
| OFF |
| 2 |
| |
| OFF |
| 3 | Disable Code required for Func. Mode Lvl. 1 |
| OFF |
| 3 |
| |
| OFF |
| 4 | Disable Code required for EZ Bypass |
| OFF |
| 4 | AuxOut Chirp on Keyfob Arm/Disarm** |
|
| OFF |
| 5 | Disable Keypad Instant Button |
| OFF |
| 5 | Disable Auxout Clear on Disarm |
|
| OFF |
| 6 | Enable Telephone |
| OFF |
| 6 | 2nd Call Answering Machine Override |
|
| OFF |
| 7 | Disable AC Fail Detection |
| OFF |
| 7 | Disable Zone Fault Scrolling (Auto Status) |
|
| OFF |
| 8 | Telco Fail only when Armed |
| OFF |
| 8 |
| |
|
|
|
| † NOTE: Not for UL Installations. |
|
|
|
|
|
|
**Default for this address contingent on EZ Menu selections.
2422 | System Options | ||
Default |
|
| Option |
|
|
|
|
ON |
| 1 | Pulse Burg Output Cadence§ |
OFF |
| 2 | Wireless Smoke Low Battery Resound |
OFF |
| 3 | Supervised Alarm Output |
OFF |
| 4 | Enable Smoke Detector Dirty Trouble |
OFF |
| 5 | Disable Area Entry Relays |
OFF |
| 6 | Disable Exit/Entry Urgency Tone at Keypad |
OFF |
| 7 | Select Bell Output on Keyfob Arming |
OFF |
| 8 | Enable Burg. Output on Telco Fail only when Armed |
§In Zone Options, Fire Zones, and only Fire Zones, must be programmed for pulse alarm output.
SYSTEM OPTIONS:
1.Select the desired option entering the option number
2.Enter corresponding option number in address location.
NOTE: Dark shaded data value box shows option not available. Press Uor Dto save.
| 3874 | System Options |
| ||
| Default |
|
| Option |
|
|
|
|
|
|
|
| OFF |
| 1 | Enable |
|
| OFF |
| 2 | Enable Cancel Report to Telco 3 |
|
| OFF |
| 3 | Wireless Trouble to Telco 1 |
|
| OFF |
| 4 | Wireless Trouble to Telco 3 |
|
| OFF |
| 5 | Enable Set Time/Date Message | SYSTEM |
| OFF |
| 6 | RESERVED | |
|
|
| |||
| ON |
| 7 | Enable Keypad Time/Date Display |
|
|
|
| 8 | RESERVED |
|
|
|
|
|
| OPTIONS |
| 3905 | System Options | |||
|
| ||||
| Default |
|
| Option |
|
|
|
|
|
|
|
| OFF |
| 1 | RESERVED |
|
| OFF |
| 2 | Enable Exit Delay Restart |
|
| OFF |
| 3 | Enable Bell on Exit Error** |
|
| OFF |
| 4 | Enable Report Exit Err/Recent Close** |
|
| OFF |
| 5 | Digital Dialer Rpt Enter/Exit Test Mode** |
|
| OFF |
| 6 | Enable |
|
| OFF |
| 7 | Disable Call Waiting on First Attempt |
|
| OFF |
| 8 | Enable Ambush in User Assignment Code Type |
|
**Default for this addresses contingent on EZ Menu selections.
ALARM/TROUBLE REPORTING CODES (ADDRESS 3880 - 3881)
ALARM/TROUBLE | ADDRESS | |
REPORTING CODES |
|
|
|
|
|
Wireless Supervisory | 3880 |
|
|
|
|
Wireless Tamper | 3881 |
|
[Default = blank (•) from address
ALARM/TROUBLE REPORTING CODES:
1.Enter in corresponding address location (left and right digits).
NOTE: Left digit is the first digit and right digit is the second digit in a two digit CS receiver format.
2.Valid entries are:
NOTE: A is not permitted.
3.To disable a code leave boxes blank (•).
4.Press Uor Dto save.
LNAPCO Security Systems |