Page 48 | WI818G 10/05 |
EXTERNAL RELAY CONTROL
To program, follow the 5 steps below:
STEP 1: RELAY # OPTIONS: Each relay/entry can be assigned to any of the 24 available external relays from Relay Module RM3008. Multiple entries can drive the same External Relay.
Select the relay number from Table 1 (shown on next page); enter in corresponding left and right digit address locations.
Note: Entries
RELAY EVENT OPTIONS
RELAY # | AREA | Timeout | Event ID | COND. | ||||||
L | R | L | R |
|
|
| L | R | L | R |
(•) |
| (•) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Step | Step | Step | Step | Step |
1 | 2 | 3 | 4 | 5 |
EXTERNAL RELAY CONTROL
STEP 2: AREA OPTIONS: Each relay/entry can be assigned to Area 1 or 2 or both areas. |
|
Select the area from Table 2 (shown on next page); enter in corresponding left and right digit |
|
address locations. |
|
STEP 3: TIMEOUTS: Each relay event can be assigned a timeout depending on Alarm Type option. |
|
If Alarm Type is selected for timeout in minutes or seconds, enter the |
|
sponding address location. To choose seconds or minutes, see step 5A below. 254 is maximum entry. |
|
STEP 4: EVENT ID CODES: Each relay event can be assigned any of the available event IDs from the table. |
|
Select |
|
STEP 5: RELAY EVENT CONDITION OPTIONS: Each relay event can be assigned an alarm type; and an activation |
|
condition; also, select a timeout type for each. |
|
5A. Select Alarm Type and Timeout Type from Table 5A (see page 51); enter in corresponding address location (left digit). | Continued |
NOTE: Select Timeout from Step 3. |
|
5B. Select Activation from from Table 5B (see page 51); enter in corresponding address location (right digit). |
|