Napco Security Technologies GEM-P3200 Acm Options, KEYPAD HOME AREA / ACM DOOR #1 AREA HEX

Models: GEM-P3200

1 68
Download 68 pages 33.66 Kb
Page 40
Image 40
ACM OPTIONS

ACM OPTIONS

Page 40

WI818G 10/05

KEYPAD HOME AREA / ACM DOOR #1 AREA (HEX)

(ADDRESS 2425 - 2431)

ACM ZONE OPTIONS:

Enter the Zone numbers (in two-digit hexadecimal format) for each option in the table below.

The left digit (nibble) determines the type of device: "●" for Keypad and "1" for ACM.

The right digit (nibble) determines the home area (1 or 2) of the specified device.

Press Uor Dto save.

KEYPAD HOME AREA / ACM DOOR #1 AREA (HEX)

(ADDRESS 2425 - 2431)

ACM / Keypad

ADDRESS

DEVICE TYPE

AREA # (1 or 2)

(●) or 1

 

 

 

1

2425

See *Note at bottom

 

22426

32427

42428

52429

62430

72431

[Default = blank (•) 1 for address 2425

blank (•) blank (•) for addresses 2426-2431]

*Note: First device should be a keypad.

XGEM-P3200 Programming Instructions

LNAPCO Security Systems

Page 40
Image 40
Napco Security Technologies GEM-P3200 Acm Options, KEYPAD HOME AREA / ACM DOOR #1 AREA HEX, Address, Acm Zone Options