Page 50 | WI818G 10/05 |
STEP 4: EVENT ID CODES: Each relay event can be assigned any of the available event IDs from the table.
Select
EXTERNAL RELAY CONTROL
TABLE 4
EVENT ID CODES
DATA ENTRIES | OPTION | |
LEFT | RIGHT |
|
blank (•) | blank (•) | Area 1 Arm |
blank (•) | 1 | Area 2 Arm |
C | blank (•) | Area 1 disarm |
C | 1 | Area 2 disarm |
blank (•) | 8 | Zone 1 |
blank (•) | 9 | Zone 2 |
blank (•) | 0 | Zone 3 |
blank (•) | B | Zone 4 |
blank (•) | C | Zone 5 |
blank (•) | D | Zone 6 |
blank (•) | E | Zone 7 |
blank (•) | F | Zone 8 |
1 | blank (•) | Zone 9 |
1 | 1 | Zone 10 |
1 | 2 | Zone 11 |
1 | 3 | Zone 12 |
1 | 4 | Zone 13 |
1 | 5 | Zone 14 |
1 | 6 | Zone 15 |
1 | 7 | Zone 16 |
1 | 8 | Zone 17 |
1 | 9 | Zone 18 |
1 | 0 | Zone 19 |
1 | B | Zone 20 |
1 | C | Zone 21 |
1 | D | Zone 22 |
1 | E | Zone 23 |
1 | F | Zone 24 |
2 | blank (•) | Zone 25 |
2 | 1 | Zone 26 |
2 | 2 | Zone 27 |
2 | 3 | Zone 28 |
2 | 4 | Zone 29 |
2 | 5 | Zone 30 |
2 | 6 | Zone 31 |
2 | 7 | Zone 32 |
2 | 8 | Zone 33 |
2 | 9 | Zone 34 |
2 | 0 | Zone 35 |
2 | B | Zone 36 |
2 | C | Zone 37 |
2 | D | Zone 38 |
2 | E | Zone 39 |
2 | F | Zone 40 |
3 | blank (•) | Zone 41 |
3 | 1 | Zone 42 |
3 | 2 | Zone 43 |
3 | 3 | Zone 44 |
3 | 4 | Zone 45 |
3 | 5 | Zone 46 |
3 | 6 | Zone 47 |
3 | 7 | Zone 48 |
6 | 8 | Area 1 Keypad Ambush |
6 | 9 | Area 1 Keypad Panic |
6 | 0 | Area 1 Keypad Fire |
6 | B | Area 1 Keypad Medical |
6 | C | Keypad Tamper |
6 | D | Area 1 Fail to Open |
6 | E | Area 1 Fail to Close |
7 | blank (•) | Area 2 Keypad Ambush |
7 | 1 | Area 2 Keypad Panic |
7 | 2 | Area 2 Keypad Fire |
7 | 3 | Area 2 Keypad Medical |
7 | 5 | Area 2 Fail to Open |
7 | 6 | Area 2 Fail to Close |
0 | 8 | Test Timer |
0 | 0 | Bus Fail |
0 | B | Guarded RAM Fail |
0 | C | Low Battery |
0 | D | AC Fail |
0 | E | EZM Tamper |
0 | F | Sensor Watch |
B | blank (•) | Telco Fault |
B | 8 | Digital Dialer Test |
B | 9 | RESERVED |
B | B | Service Message |
B | C | Program Change |
B | D | RF Receiver Trouble |
B | E | Transmitter Tamper |
B | F | Transmitter Trouble |
D | blank (•) | Keypad Fail |
D | 1 | EZM Fail |
D | 2 | Quickloader Device Control |
D | 3 | System Shutdown |
D | 4 | Quickloader Keypad Reset |
D | 5 | General System Alarm |
D | 8 | Area 1 General System Alarm |
D | 9 | Area 2 General System Alarm |
F | blank (•) | Relay Group 1 |
F | 1 | Relay Group 2 |
F | 8 | Area 1 Entry Delay |
F | 9 | Area 2 Entry Delay |
NOTE: Keypad Tamper must be enabled in UL installations using jumper op- tion on keypad.
Continued