Chime 2 Zones Enter Zone # °°
(Direct Entry)
Exit/Entry2 Zones Enter Zone # °°
(Direct Entry)
50mS Loop Zones Enter Zone # °°
(Direct Entry)
Aux Output Zones
Enter Zone # ° °
(Direct Entry)
Sensor Watch Zns
Enter Zone # ° °
(Direct Entry)
KP Sndr Alrm Zns
Enter Zone # ° °
(Direct Entry)
Auto Byp REnt Zn
Enter Zone # ° °
(Direct Entry)
E nab le No EOL R
Z one s | Y/N |
| |
(Press YES or NO) | |
|
|
Enable Telco |
|
Line Test? | Y/N |
| |
(Press YES or NO) | |
|
|
Enable Burg Out |
|
Chirp? | Y/N |
|
|
(Press YES or NO)
Page 7
Chime 2 Zones in Area 1 (New Program Only)
•Enter the zone numbers which are to be used as Chime 2 Zones.
•Valid entries are from 01 to 48. Directly enter each zone number, including leading zeros.
•Press Uto save and then repeat for any additional zone(s), Press the NEXT/YES button to proceed.
NOTE: A chime time of 2 seconds will be automatically programmed.
Chime 2 zones give a distinct pulsating tone when zone is faulted.
Exit/Entry2 Zones in Area 1 (New Program Only)
•Enter the zone numbers of zones to be used as Exit/Entry zones.
•Valid entries are from 01 to 48. Directly enter each zone number, including leading zeros.
•Press Uto save and repeat for any additional zone(s); press the NEXT/YES button to proceed.
NOTE: An Entry Delay Time of 30 sec. and an Exit Delay Time of 60 sec. will automatically be programmed.
50 mS Loop Response Zones (New Program Only)
•Enter the zone numbers of zones to have a 50mS loop response.
•Valid entries are from 01 to 08. Directly enter each zone number, including leading zeros.
•Press Uto save and then repeat for any additional zone(s), Press the NEXT/YES button to proceed. Note: Only
panel zones
Aux Output Activated on Alarm Zones (New Program Only)
•Enter the zone numbers of zones to activate the Aux Output upon alarm.
•Valid entries are from 01 to 48. Directly enter each zone number, including leading zeros.
•Press Uto save and then repeat for any additional zone(s), Press the NEXT/YES button to proceed.
NOTE: An Aux Output Timeout of 15 minutes will automatically be programmed.
Sensor Watch Zones (New Program Only)
•Enter the zone numbers of zones to be Sensor Watch zones.
•Valid entries are from 01 to 48. Directly enter each zone number, including leading zeros.
•Press Uto save and then repeat for any additional zone(s), Press the NEXT/YES button to proceed.
NOTE: A Sensor Watch Time of 24 hours will automatically be programmed.
Keypad Sounder On Alarm Zones (New Program Only)
•Enter the zone numbers of all zones to activate the Keypad Sounder upon alarm.
•Valid entries are from 01 to 48. Directly enter each zone number, including leading zeros.
•Press Uto save and then repeat for any additional zone(s), Press the NEXT/YES button to proceed.
Auto Bypass
•Enter the zone numbers of zones to be Auto Bypass
•Valid entries are from 01 to 48. Directly enter each zone number, including leading zeros.
•Press Uto save and then repeat for any additional zone(s), Press the NEXT/YES button to proceed.
•Auto Bypass
Enable No EOLR Zones (New Program Only)
•Press YES to program all zones except 24 Hr & fire zones for No End Of Line Resistor. Press NO to continue.
•Do not program this feature for UL Installations.
Enable Telco Line Fault Test?
•Press YES to enable Telco Line Fault Test.
•Press NO to continue. NOTE: If enabled, a Telco Line Fault Test Delay of 60 sec. will automatically be pro- grammed.
Enable Burg Output Chirp on KeyFob?
•Press the NEXT/YES button to enable Burg Output Chirp on KeyFob Arm / Disarm.
•Press the PRIOR/NO button to continue.
NOTE: The Burg Output will chirp once on Keyfob Arm and twice on Keyfob Disarm.
LNAPCO Security Systems |