Page 16 | WI818G 10/05 |
ADDRESS PROGRAM MODE
|
|
|
| ZONES 1 | 8 |
|
|
|
|
| ZONES 9 | 16 |
|
| ||||
ZONE FEATURES | ADDR | Z1 | Z2 | Z3 | Z4 | Z5 | Z6 | Z7 | Z8 | ADDR | Z9 | Z10 | Z11 | Z12 | Z13 | Z14 | Z15 | Z16 |
|
| 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
| 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Exit/Entry Follower | 1218 |
|
|
|
|
| 6 | 7 | 8 | 1318 |
|
|
|
|
|
|
|
|
PROGRAM THE DATA ENTRIES
1.Enter the panel's Dealer Security Code, then press R.
2.Answer NO to all questions until “ACTIVATE PROGRAM Y/N” is displayed; then press YES. NOTE: If you pass “ACTIVATE PROGRAM”, scroll backward using B.
3.Press Cto enter the Address Program Mode. Address "0000" will display.
4.Press 1218to access Address 1218. The existing data will display and the cursor will advance to the data field.
5.Press 678. The numbers 6,7 and 8 will appear on the keypad display indicating the zones activated.
6.Press Uto save. Address 1218 is now programmed with “6,7,8”.
7.Press Rand enter another
B)Decimal Format
Settings (such as Entry and Exit Delay) display and accept data in decimal format, as a 3 digit number. Data is en- tered directly, by pressing keys 0 – 9, with the cursor automatically moving to the right upon each key press.
EXAMPLE: DECIMAL Format with the
2406 - - - | D |
| 2406 015 | D |
DIRECT
Address | DATA ENTRY LOCATION: |
2406 | Decimal Format |
"Abort | • No time yet entered |
Delay" |
|
|
DETERMINE THE DATA ENTRIES
Address
2406
"Abort
Delay"
DATA ENTRY LOCATION:
Decimal Format
Press 015in order to set
"Abort Delay" to 15 seconds. The "D" on the right indicates "Decimal" format.
Referring to SYSTEM DELAYS & TIMEOUTS in the Programming Worksheets that follow, the Abort Delay is lo- cated at address 2406:
ABORT ADDRESS 2406
DELAY
(sec.)
[Default = 000]
PROGRAM THE DATA ENTRIES
1.Enter the panel's Dealer Security Code, then press R.
2.Answer NO to all questions until “ACTIVATE PROGRAM Y/N” is displayed; then press YES. NOTE: If you pass “ACTIVATE PROGRAM”, scroll backward using B.
3.Press Cto enter the Address Program Mode. Address "0000" will display.
4.Press 2406to access Address 2406. The existing data will display and the cursor will
LNAPCO Security Systems |