Napco Security Technologies GEM-P3200 4091, 4093, User Program Mode, System Reset Options Address

Models: GEM-P3200

1 68
Download 68 pages 33.66 Kb
Page 52
Image 52
SYSTEM RESET OPTIONS (ADDRESS 4091 -4093)

Page 52

WI818G 10/05

SYSTEM RESET OPTIONS (ADDRESS 4091 -4093)

MODE--USER PROGRAM MODE

4091 XX

GEM-RP1CAe2/GEM-K1CA Keypad

GEM-RP2ASe2 Keypad

4091XX

4093 XX

GEM-RP1CAe2/GEM-K1CA Keypad

GEM-RP2ASe2 Keypad

4093XX

Clear Dealer Program (Erases Dealer Program)

This erases the dealer program. Use this feature to start a customized default program.

Access address 4091, then press the Jor Ubutton. Data entry is not allowed.

NOTE: Enter Easy Menu Driven Program Mode to program system again.

Cold Start (Erases Entire Program)

This erases the entire program (codes, schedules, foreign language configuration, etc), leaving the panel as it came right out of the box.

Access address 4093, then press the Jor Ubutton. Data entry is not allowed.

DIRECT ADDRESS PROGRAM

NOTE: Some features (schedules, language configuration) can only be re-programmed with the Downloading Software.

USER PROGRAM MODE

PRELIMINARY INFORMATION

The User Program Mode is covered in detail in the operating instructions for the keypad in use.

Only Keypad #1 may be used for programming, however this keypad may be located in either area.

The Program Mode cannot be accessed while the communicator is transmitting except during the first three minutes after power- up.

After entering codes or data, press the save Ubutton. Data will not be stored into memory unless this button is pressed.

If the keypad is in the Program Mode and no activity is detected for longer than 4 minutes, a steady tone will sound.

NOTE: For ease of programming, it is recommended that a GEM K1CA (or GEM-RP1CAe2) be used as Keypad #1. A new GEM- K1CA and a new GEM-RP1CAe2 are automatically configured as Keypad #1. See Keypad Configuration Mode.

Press the Cbutton to silence the sounder and exit the User Program Mode.

If a GEM-RP2ASe2/GEM-K2AS keypad is used, configure address jumpers as Keypad #1 (See WI1184).

XGEM-P3200 Programming Instructions

LNAPCO Security Systems

Page 52
Image 52
Napco Security Technologies GEM-P3200 4091, 4093, User Program Mode, System Reset Options Address, Mode--Userprogram Mode