Page 52 | WI818G 10/05 |
SYSTEM RESET OPTIONS (ADDRESS 4091 -4093)
MODE--USER PROGRAM MODE
4091 XX
4091XX
4093 XX
4093XX
Clear Dealer Program (Erases Dealer Program)
This erases the dealer program. Use this feature to start a customized default program.
Access address 4091, then press the Jor Ubutton. Data entry is not allowed.
NOTE: Enter Easy Menu Driven Program Mode to program system again.
Cold Start (Erases Entire Program)
This erases the entire program (codes, schedules, foreign language configuration, etc), leaving the panel as it came right out of the box.
Access address 4093, then press the Jor Ubutton. Data entry is not allowed.
DIRECT ADDRESS PROGRAM
NOTE: Some features (schedules, language configuration) can only be
USER PROGRAM MODE
PRELIMINARY INFORMATION
The User Program Mode is covered in detail in the operating instructions for the keypad in use.
Only Keypad #1 may be used for programming, however this keypad may be located in either area.
The Program Mode cannot be accessed while the communicator is transmitting except during the first three minutes after power- up.
After entering codes or data, press the save Ubutton. Data will not be stored into memory unless this button is pressed.
If the keypad is in the Program Mode and no activity is detected for longer than 4 minutes, a steady tone will sound.
NOTE: For ease of programming, it is recommended that a GEM K1CA (or
Press the Cbutton to silence the sounder and exit the User Program Mode.
If a
LNAPCO Security Systems |