Napco Security Technologies GEM-P3200 quick start Global System Trouble Reporting Options

Models: GEM-P3200

1 68
Download 68 pages 33.66 Kb
Page 28
Image 28
GLOBAL SYSTEM TROUBLE REPORTING OPTIONS

GLOBAL SYSTEM TROUBLE REPORTING OPTIONS

 

Page 28

 

 

 

 

 

 

 

 

 

WI818G 10/05

 

GLOBAL SYSTEM TROUBLE REPORTING OPTIONS (ADDRESS 1082 - 1116)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SYSTEM RESPONSE

 

 

 

GLOBAL SYSTEM EVENT/TROUBLE

 

 

 

 

ADDR

TEST

ALARM

 

COMM.

MEMORY

LOW

AC FAIL

 

EZM

SENSOR

 

 

ACTIVATED BY GLOBAL

 

TIMER

SUPERV.

 

BUS 1

FAILURE

BATTERY

 

 

TAMPER

WATCH

 

 

 

1

2

 

3

4

5

6

 

7

8

 

 

EVENT/TROUBLE

 

 

 

 

 

Burglary Alarm Output

1082

 

 

 

 

 

 

 

 

 

 

 

 

Pulsed Burg. Output

1083

 

 

 

 

 

 

 

 

 

 

 

 

Fire Output (Lug E9)

1084

 

 

 

 

 

 

 

 

 

 

 

 

Reset Relay

1085

 

 

 

 

 

 

 

 

 

 

 

 

Auxiliary Relay

1086

 

 

 

 

 

 

 

 

 

 

 

 

Report Event Telco 1

1087

 

 

 

 

 

 

 

 

 

 

 

 

Report Restore Telco 1

1088

 

 

 

 

 

 

 

 

 

 

 

 

Report Event Telco 3

1091

 

 

 

 

 

 

 

 

 

 

 

 

Report Restore Telco 3

1092

 

 

 

 

 

 

 

 

 

 

 

[Default = blank (•) from address 1082-1092].

SYSTEM RESPONSE

 

 

 

GLOBAL SYSTEM EVENT/TROUBLE

 

 

ACTIVATED BY GLOBAL

ADDR

TELCO

RSRVD.

Telemetry

Telemetry

RSRVD.

RSRVD.

RSRVD.

RSRVD.

EVENT/TROUBLE

 

FAIL

Trouble

Failure

 

1

2

3

4

5

6

7

8

Burglary Alarm Output

1094

 

 

 

 

 

 

 

 

Pulsed Burg. Output

1095

 

 

 

 

 

 

 

 

Fire Output (Lug E9)

1096

 

 

 

 

 

 

 

 

Reset Relay

1097

 

 

 

 

 

 

 

 

Auxiliary Relay

1098

 

 

 

 

 

 

 

 

Report Event Telco 1

1099

 

 

 

 

 

 

 

 

Report Restore Telco 1

1100

 

 

 

 

 

 

 

 

Report Event Telco 3

1103

 

 

 

 

 

 

 

 

Report Restore Telco 3

1104

 

 

 

 

 

 

 

 

[Default = blank (•) from address 1094-1104]

* NOTE: Keypad Aux. is not to be selected for UL Installations.

 

SYSTEM RESPONSE

 

 

 

GLOBAL SYSTEM EVENT/TROUBLE

 

 

ACTIVATED BY GLOBAL

ADDR

Digital

RSRVD.

 

RSRVD.

SERVICE

PROGRAM

RF RCVR.

 

RF

RF

Dialer Test

 

MESSAGE

CHANGE

TROUBLE

 

TAMPER

TROUBLE

EVENT/TROUBLE

 

 

 

 

 

 

 

 

 

 

 

 

1

2

 

3

4

5

6

 

7

8

Burglary Alarm Output

1106

 

 

 

 

 

 

 

 

 

 

Pulsed Burg. Output

1107

 

 

 

 

 

 

 

 

 

 

Fire Output (Lug E9)

1108

 

 

 

 

 

 

 

 

 

 

Reset Relay

1109

 

 

 

 

 

 

 

 

 

 

Auxiliary Relay

1110

 

 

 

 

 

 

 

 

 

 

Report Event Telco 1

1111

 

 

 

 

 

 

 

 

 

 

Report Restore Telco 1

1112

 

 

 

 

 

 

 

 

 

 

Report Event Telco 3

1115

 

 

 

 

 

 

 

 

 

 

Report Restore Telco 3

1116

 

 

 

 

 

 

 

 

 

 

[Default = blank (•) blank (•) from address 1106-1116] * NOTE: Keypad Aux. is not to be selected for UL Installations.

1.Select the desired option entering the option number (1-8) for each digit.

2.Enter corresponding option number in address location.

NOTE: Dark shaded data value box shows option not available. Press Uor Dto save.

XGEM-P3200 Programming Instructions

LNAPCO Security Systems

Page 28
Image 28
Napco Security Technologies GEM-P3200 quick start Global System Trouble Reporting Options