Page 49

 

 

 

 

 

 

 

 

 

 

 

EXTERNAL RELAY CONTROL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RELAY EVENT OPTIONS

 

 

 

 

 

 

 

 

 

 

 

RELAY #

AREA

TIMEOUT

EVENT ID

COND.

 

 

 

 

See

See

See

See

See

 

 

 

 

Table 1 below

Table 2 below

Table 3 below

Table 4 on page 50

Tables 5A & 5B on

 

 

 

 

 

 

 

 

page 51

 

 

 

 

 

 

 

 

 

 

 

 

 

TABLE 1

 

 

RELAY MAPPING

 

DATA ENTRIES

 

RELAY #

LEFT

 

RIGHT

 

 

 

 

blank (•)

 

blank (•)

 

None *

blank (•)

 

1

 

1

blank (•)

 

2

 

2

blank (•)

 

3

 

3

blank (•)

 

4

 

4

blank (•)

 

5

 

5

blank (•)

 

6

 

6

blank (•)

 

7

 

7

blank (•)

 

8

 

8

blank (•)

 

9

 

9

blank (•)

 

0

 

10

blank (•)

 

B

 

11

blank (•)

 

C

 

12

blank (•)

 

D

 

13

blank (•)

 

E

 

14

blank (•)

 

F

 

15

1

 

blank (•)

 

16

1

 

1

 

17

1

 

2

 

18

1

 

3

 

19

1

 

4

 

20

1

 

5

 

21

1

 

6

 

22

1

 

7

 

23

1

 

8

 

24

* Note: [blank

(•) blank (•)]

option affects the

relay with the same entry number. All other

options affect the relay number specified. Ex:

Suppose Relay/Entry 1 is mapped to External

Relay 1 and Relay/Entry 2 is mapped to

External Relay 24. The data entries are as

follows: Address 3778 = [blank (•) blank (•)] and

Address 3779 = [1C].

 

Areas

1-2

TABLE 2 (AREAS 1-2)

AREAS CONTROLLING RELAY

SHUTOFF ON DISARM

RIGHT DATA

AREA 1

AREA 2

ENTRY

 

 

 

 

 

blank (•)

NONE

1

Y

 

 

 

 

2

 

Y

 

 

 

3

Y

Y

 

 

 

Note: “Y” indicates option is enabled.

TIMEOUTS: Each relay event can be assigned a timeout depending on Alarm Type option.

If Alarm Type is selected for timeout in

minutes or seconds, enter the 3-digit time- out duration in corresponding address location. To choose seconds or minutes, see step 5A on page 51. Maximum entry is 254.

EXTERNAL RELAY CONTROL

For a desired relay not listed:

 

 

 

 

 

Quotient

 

 

 

Left Digit

A. Choose a desired relay, ex: 60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B. Divide it by 16

16

60

 

 

 

 

 

 

 

 

 

 

48

 

Remainder

 

 

Right Digit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Continued

LNAPCO Security Systems

XGEM-P3200 Programming Instructions

Page 49
Image 49