ACM DOOR AREA OPTIONS (ADDRESS 2784 - 2787)

WI818G 10/05

Page 39

ACM DOOR AREA OPTIONS (ADDRESS 2784 - 2787)

ACM DOOR AREA OPTIONS:

1.Select the desired option entering the option number (1-3) for each address.

2.Enter corresponding option number in address location.

NOTE: Dark shaded data value box shows option not available. Press Uor Dto save.

 

 

 

 

ACM DOOR AREA OPTIONS

 

 

ACM Door Number

ADDR

Arm All

Disarm All

Stealth

 

 

 

 

 

Areas

Areas

 

RSRVD.

RSRVD.

RSRVD.

RSRVD.

RSRVD.

 

 

Allowed

Allowed

 

Mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

 

3

4

5

6

7

8

ACM 1 - Door 1

2784

 

 

 

 

 

 

 

 

 

ACM 1 - Door 2

2785

 

 

 

 

 

 

 

 

 

ACM 2 - Door 1

2786

 

 

 

 

 

 

 

 

 

ACM 2 - Door 2

2787

 

 

 

 

 

 

 

 

 

 

[Default = blank (•) blank (•) from address 2784-2787]

 

 

 

 

ACM SCHEDULED FREE ACCESS (ADDRESS 4072 - 4075)

ACM OPTIONS

ACM SCHEDULED FREE ACCESS:

1.Enter the Scheduled Free Access Index (1-24) (Relay #1-24) for each option in the table at right.

2.Press Uor Dto save.

Scheduled Free Access Index

ADDR

Relay Number

ACM 1 – Door 1 – 4072

ACM 1 – Door 2 – 4073

ACM 2 – Door 1 – 4074

ACM 2 – Door 2 – 4075

[Default = blank (•) blank (•) from address 4072-4075]