NUMBER OF RELAY BOARD MODULES (ADDRESS 3777)
Each relay event can be assigned an alarm type; and an activation condition; also, select a

WI818G 10/05

Page 51

STEP 5: RELAY EVENT CONDITION OPTIONS: timeout type for each.

5A. Select Alarm Type and Timeout Type from Table 5A (below); enter in corresponding address location (left digit). NOTE: Select Timeout from Step 3.

5B. Select Activation from from Table 5B (below); enter in corresponding address location (right digit).

TABLE 5A

RELAY EVENT

ALARM TYPE OPTIONS

LEFT DATA

ALARM

TIMEOUT

ENTRIES

TYPE

TYPE

blank (•)

Burglary

Minutes

1

Fire

Minutes

4

Day Zone

Minutes

8

Burglary

Seconds

9

Fire

Seconds

C

Day Zone

Seconds

TABLE 5B

RELAY EVENT

ACTIVATION CONDITIONS

RIGHT DATA ENTRIES

OPTIONS

1Alarm

2Restore

3Trouble

4Trouble Restore

5Follows Open Zone

6Follows Shorted Zone

NUMBER OF RELAY BOARD MODULES (ADDRESS 3777)

EXTERNAL

ADDRESS 3777

Number of Relay

LEFT

RIGHT

Board Modules

blank (•)

 

[Default = blank (•) blank (•)]

 

DATA

Relay Board Module(s)

 

 

RIGHT

 

blank (•)

 

 

 

None

11

22

33

RELAY BOARD MODULES: Up to 3 External Relay Board Modules (RM3008) may be programmed.

1.Select the number of relay modules from the table shown.

2.Enter in corresponding right digit address location shown (left digit is not used).

RELAY CONTROL

LNAPCO Security Systems

XGEM-P3200 Programming Instructions