Napco Security Technologies GEM-P3200 0900, CHexadecimal Format, Direct Address, Program Mode

Models: GEM-P3200

1 68
Download 68 pages 33.66 Kb
Page 17
Image 17
advance to the data field.

WI818G 10/05

Page 17

advance to the data field.

5.Press 015. The numbers 015 will appear on the keypad display indicating the number of seconds entered.

6.Press Uto save. Address 2406 is now programmed with a 15-second Abort Delay.

7.Enter another 4-digit address to continue programming or press Cto exit and resume normal keypad operation.

C)Hexadecimal Format

Data such as Report Codes displays, accepts data by means of a Hexadecimal display. Data is entered directly, by pressing keys 1 – 9, G0for zero, and G1through G5for hex B through F (11-15), with the

cursor automatically moving to the right upon key press. See table below.

HEXADECIMAL ENTRIES

ENTRY

PRESS

KEYPAD

 

ENTRY

PRESS

KEYPAD

TOTAL

N

DISPLAYS

 

TOTAL

N

DISPLAYS

 

 

 

 

 

 

 

 

 

 

blank

0

 

8

8

8

 

 

 

 

 

 

 

 

 

 

 

1

1

1

 

9

9

9

 

 

 

 

 

 

 

 

 

 

2

2

2

 

10

G 0

0

 

 

 

 

 

 

 

 

 

 

3

3

3

 

11

G 1

B

 

 

 

 

 

 

 

 

 

 

4

4

4

 

12

G 2

C

 

 

 

 

 

 

 

 

 

 

5

5

5

 

13

G 3

D

 

 

 

 

 

 

 

 

 

 

6

6

6

 

14

G 4

E

 

 

 

 

 

 

 

 

 

 

7

7

7

 

15

G 5

F

 

 

 

 

 

 

 

 

 

 

EXAMPLE: HEXADECIMAL Format with the GEM-RP1CAe2/GEM-K1CA: Program an Ambush CS Reporting Code to be

"1B".

DIRECT ADDRESS

 

0900

- -

H

 

 

 

 

 

 

 

 

 

 

 

 

 

Address

 

DATA ENTRY LOCATION:

 

0900

 

 

Hex Format

 

 

"Ambush"

 

No data yet entered

 

 

 

 

 

 

 

 

 

 

 

 

 

DETERMINE THE DATA ENTRIES

 

0900

1 B

H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Address

 

 

 

DATA ENTRY LOCATION:

0900

 

 

 

 

 

Hex Format

"Ambush"

 

 

Press 1G1in order to set

 

 

 

 

 

"Ambush" Reporting code to "1B". The "H"

 

 

 

 

 

on the right indicates "Hexadecimal" format.

 

 

 

 

 

 

 

 

 

PROGRAM MODE

Referring to CS REPORTING CODES in the Programming Worksheets that follow, Ambush is located at address 0900. In the "Keypad Reporting Codes" table, the data entries needed to assign a code of "1B" are "1" and "G1".

KEYPAD REPORTING

 

ADDRESS

 

 

0900-0904

 

CODES

 

 

LEFT

 

ADDR

 

RIGHT

 

 

 

Ambush

1

 

0900

 

B

Panic

 

 

 

 

 

 

 

0901

 

 

Fire

 

 

 

 

 

 

 

0902

 

 

Auxiliary

 

 

 

 

 

 

 

0903

 

 

Tamper

 

 

 

 

 

 

 

0904

 

 

 

 

 

 

 

 

LNAPCO Security Systems

XGEM-P3200 Programming Instructions

Page 17
Image 17
Napco Security Technologies GEM-P3200 0900, CHexadecimal Format, Direct Address, Program Mode, advance to the data field