WI818G 10/05 | Page 33 |
ZONE OPTIONS / ZONES 1- 48 (ADDRESS 1200 -1786)
ZONE OPTIONS: Select zone options for any zone.
1.Select the desired zone option by entering the option number
2.Enter corresponding option number in address location, in Binary (Bit) Format.
NOTE: Dark shaded data value box shows option not available. Press Uor Dto save
NOTE: See Direct Address Programming Example on page 15.
NOTES: (A) 50ms & 20 ms Loop Response only available for zones
(B)
(C)If Fire Alarm Verification is selected, then Fire must also be selected.
DEFAULTS: The zone options indicated are automatically set after exiting the Easy Menu Driven Mode.
Priority, Selective Bypass, Alarm Output, Auto Reset, Swinger Shutdown , Zone Area 1 and Zone Area 2 are enabled for the total number of zones entered in “AREA 1 # ZONES = 08” and “AREA 2 # ZONES = 00”.
Alarm Telco 1 is enabled for the zones if [YES] is entered for “REPORT ALL ZONES TO CENTRAL ZONES? Y/N”.
Entry/Exit 1 and Chime are enabled for zone numbers entered in “EXIT / ENTRY ZONES”.
Exit/Entry Follower and Interior Bypass are enabled for zone numbers entered in “INTERIOR ZONES”.
Fire, Pulse Alarm Output and Fire Verification is enabled for the zone numbers entered in “FIRE ZONES”.
Note: See “Number of Zones
&Keypads per Area” in Easy Menu Driven program Mode.