Page 32

WI818G 10/05

ZONE OPTIONS / ZONES 33 - 48 (ADDRESS 1602 -1786)

ZONE OPTIONS / ZONES 33-48

 

 

 

 

ZONES 33

40

 

 

 

 

 

ZONES 41

48

 

 

ZONE OPTIONS

ADDR

Z33

Z34

Z35

Z36

Z37

Z38

Z39

Z40

ADDR

Z41

Z42

Z43

Z44

Z45

Z46

Z47

Z48

 

 

1

2

3

4

5

6

7

8

 

1

2

3

4

5

6

7

8

Priority

1602

 

 

 

 

 

 

 

 

1702

 

 

 

 

 

 

 

 

Priority with Bypass

1603

 

 

 

 

 

 

 

 

1703

 

 

 

 

 

 

 

 

Auto-Bypass

1604

 

 

 

 

 

 

 

 

1704

 

 

 

 

 

 

 

 

Selective Bypass

1605

 

 

 

 

 

 

 

 

1705

 

 

 

 

 

 

 

 

Keyswitch Arming

1606

 

 

 

 

 

 

 

 

1706

 

 

 

 

 

 

 

 

Auto-Bypass Re-entry

1607

 

 

 

 

 

 

 

 

1707

 

 

 

 

 

 

 

 

Pre-Alarm Warning

1608

 

 

 

 

 

 

 

 

1708

 

 

 

 

 

 

 

 

Never Arm

1609

 

 

 

 

 

 

 

 

1709

 

 

 

 

 

 

 

 

24-Hour Zone

1610

 

 

 

 

 

 

 

 

1710

 

 

 

 

 

 

 

 

Burg. Alarm Output

1611

 

 

 

 

 

 

 

 

1711

 

 

 

 

 

 

 

 

Pulsed Alarm Output

1612

 

 

 

 

 

 

 

 

1712

 

 

 

 

 

 

 

 

Fire Output (Lug E9)

1613

 

 

 

 

 

 

 

 

1713

 

 

 

 

 

 

 

 

Reset Relay

1614

 

 

 

 

 

 

 

 

1714

 

 

 

 

 

 

 

 

Auxiliary Relay

1615

 

 

 

 

 

 

 

 

1715

 

 

 

 

 

 

 

 

Entry/Exit 1

1616

 

 

 

 

 

 

 

 

1716

 

 

 

 

 

 

 

 

Entry/Exit 2

1617

 

 

 

 

 

 

 

 

1717

 

 

 

 

 

 

 

 

Exit/Entry Follower

1618

 

 

 

 

 

 

 

 

1718

 

 

 

 

 

 

 

 

Auto Reset

1619

 

 

 

 

 

 

 

 

1719

 

 

 

 

 

 

 

 

Swinger Shutdown

1620

 

 

 

 

 

 

 

 

1720

 

 

 

 

 

 

 

 

Chime

1621

 

 

 

 

 

 

 

 

1721

 

 

 

 

 

 

 

 

Abort Delay

1622

 

 

 

 

 

 

 

 

1722

 

 

 

 

 

 

 

 

Power-up Delay

1623

 

 

 

 

 

 

 

 

1723

 

 

 

 

 

 

 

 

Day Zone Open

1624

 

 

 

 

 

 

 

 

1724

 

 

 

 

 

 

 

 

Day Zone Short

1625

 

 

 

 

 

 

 

 

1725

 

 

 

 

 

 

 

 

Alarm on Day Zone

1626

 

 

 

 

 

 

 

 

1726

 

 

 

 

 

 

 

 

RPT Alarm Tel 1

1627

 

 

 

 

 

 

 

 

1727

 

 

 

 

 

 

 

 

RPT Alarm Restore Tel 1

1628

 

 

 

 

 

 

 

 

1728

 

 

 

 

 

 

 

 

RPT Trouble Tel 1

1629

 

 

 

 

 

 

 

 

1729

 

 

 

 

 

 

 

 

RPT Trouble Restore Tel 1

1630

 

 

 

 

 

 

 

 

1730

 

 

 

 

 

 

 

 

RPT Alarm Tel 3

1635

 

 

 

 

 

 

 

 

1735

 

 

 

 

 

 

 

 

RPT Alarm Restore Tel 3

1636

 

 

 

 

 

 

 

 

1736

 

 

 

 

 

 

 

 

RPT Trouble Tel 3

1637

 

 

 

 

 

 

 

 

1737

 

 

 

 

 

 

 

 

RPT Trouble Restore Tel 3

1638

 

 

 

 

 

 

 

 

1738

 

 

 

 

 

 

 

 

No EOL Resistor

1639

 

 

 

 

 

 

 

 

1739

 

 

 

 

 

 

 

 

Sensor Watch

1640

 

 

 

 

 

 

 

 

1740

 

 

 

 

 

 

 

 

Trouble on Open

1641

 

 

 

 

 

 

 

 

1741

 

 

 

 

 

 

 

 

Trouble on Short

1642

 

 

 

 

 

 

 

 

1742

 

 

 

 

 

 

 

 

Trouble on Night Open

1643

 

 

 

 

 

 

 

 

1743

 

 

 

 

 

 

 

 

Zone Area 1

1644

 

 

 

 

 

 

 

 

1744

 

 

 

 

 

 

 

 

Zone Area 2

1645

 

 

 

 

 

 

 

 

1745

 

 

 

 

 

 

 

 

RESERVED

1653

 

 

 

 

 

 

 

 

1753

 

 

 

 

 

 

 

 

Zone ANDing Group 1

1654

 

 

 

 

 

 

 

 

1754

 

 

 

 

 

 

 

 

Zone ANDing Group 2

1655

 

 

 

 

 

 

 

 

1755

 

 

 

 

 

 

 

 

Interior #1 Bypass

1662

 

 

 

 

 

 

 

 

1762

 

 

 

 

 

 

 

 

Interior #2 Bypass

1663

 

 

 

 

 

 

 

 

1763

 

 

 

 

 

 

 

 

Keypad Sounder on Alarm

1664

 

 

 

 

 

 

 

 

1764

 

 

 

 

 

 

 

 

Fire (C)

1675

 

 

 

 

 

 

 

 

1775

 

 

 

 

 

 

 

 

Fire Alarm Verification (C)

1676

 

 

 

 

 

 

 

 

1776

 

 

 

 

 

 

 

 

Interior (STAY) Bypass

1684

 

 

 

 

 

 

 

 

1784

 

 

 

 

 

 

 

 

Chime 2

1686

 

 

 

 

 

 

 

 

1786

 

 

 

 

 

 

 

 

When the Easy Program Menu is used, these features are enabled by default (for new panels or after a Cold Start (address 4093)). Do not program if "K Series" keypads (with "P" and "Q" buttons) are used in the system.

Disable Auto-Reset on non-fire zones for SIA CP-01 installations.

In UL installations, all Fire Zones must also be programmed for "Pulse Burg Output Cadence" (Address 2422, press 1 (bit zero)).

See Zone Options on Page 33.

XGEM-P3200 Programming Instructions

LNAPCO Security Systems

Page 32
Image 32
Napco Security Technologies GEM-P3200 quick start Zone Options / Zones 33 48 Address 1602, See Zone Options on