WI818G 10/05

SYSTEM DELAYS & TIMEOUTS (ADDRESS 2400, 2401, 2403- 2405, 4082 & 4083)

CODES

Reset Output

ADDRESS 2400

 

Aux. Output

ADDRESS 2401

 

Burg. Alarm

ADDRESS 2403

 

Pulse Alarm

ADDRESS 2404

Timeout

 

 

 

 

Timeout

 

 

 

 

Output

 

 

 

 

Output

 

 

 

(min.)

 

 

 

 

(min.)

 

 

 

 

Timeout

 

 

 

 

Timeout

 

 

 

 

 

 

 

 

 

 

 

 

 

(min.)

 

 

 

 

(min.)

 

 

 

[Default = 000]

 

[Default = 000]

 

[Default = 015]

 

[Default = 015]

1.Select delay/timeout (0-255 min.).

2.Enter in corresponding address locations above and right.

3.Press Uor Dto save.

OUTPUT TIMEOUTS: If a timeout of “0 min.” is selected, then the output will remain active (ON) until the system is reset or disarmed. For UL Residential In- stallations, the minimum timeout is 4 minutes. For UL Commercial Installations, the minimum timeout is 15 minutes.

Fire Output

ADDRESS 2405

Timeout

 

 

 

(min.)

 

 

 

 

 

 

 

[Default = 000]

 

 

Report

ADDRESS 4082

Cancel

 

 

 

Window

 

 

 

(min or sec.)

 

 

 

[Default = 000]

V.1 or less = sec.

V.3 or greater = min.

Program for at least 5 minutes in a CP-01 installation.*

Auto Disarm ADDRESS 4083

Rearm Delay

(min.)

[Default = 000]

SYSTEM DELAYS/TIMEOUTS & KEYPAD

*Address 4082: When "Enable CP-01 Features" is selected in the Easy Program menu, this time is set to 7 minutes.

KEYPAD SYSTEM CODES (ADDRESS 0490 - 0495 & 0500 - 0502)

 

ADDRESS 0490-0492

Panel Access

0490

0491

0492

Code

L

R

L

R

L

R

 

 

 

 

 

 

 

[Default = blank (•) blank (•) from address 0490-0492]

PANEL ACCESS CODE: Enter up to 6 digits to activate a door strike while the area is disarmed.

1.Enter in both left and right digits of address locations.

2.Valid entries are: 0-9.

Note: Also, “Access Control on Aux. Output” (Address 2418) and “Aux. Output Access Control Timeout” (Address 2402) must both be enabled.

Ambush

ADDRESS 0495

LEFT

RIGHT

Code

 

 

 

 

 

[Default = 99]

AMBUSH CODE: Enter a 2-digit code used just prior to disarming and will activate an Ambush Condition, causing a SILENT report to be sent to the central station.

1.Enter in both left and right digits of address locations.

2.Valid entries are: 0-9.

Note: Also, “Enable Keypad Ambush” (Address 2440-2446), “Report on Ambush Alarm” (Address 1125, 1127, 1135 & 1137) must be enabled and “Ambush Reporting Code” (Address 0900) must be provided.

Dealer Security

ADDRESS 0500-0502

0500

0501

0502

Code

L

R

L

R

L

R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[Default = blank (•) blank (•) from address 0500-0502]

DEALER SECURITY CODE: Enter up to 6 digits to be used by the dealer to enter programming.

1.Enter in both left and right digits of address locations.

2.Valid entries are: 0-9.

Note: If left blank, the Master Security Code must then be used to enter programming.

XGEM-P3200 Programming Instructions