PERIODIC MAINTENANCE
TEMPERATURE-PRESSURE
RELIEF VALVE OPERATION
The
When checking the
FIGURE 12.
If after manually operating the valve, it fails to completely reset and continues to release water, immediately close the cold water inlet to the water heater, follow the draining instructions, and replace the
If the
DRAINING
The water heater should be drained if being shut down during freezing temperatures. Also periodic draining and cleaning of sediment from the tank may be necessary.
1.Turn electrical supply “OFF”.
2.CLOSE the cold water inlet valve to the water heater.
3.OPEN a nearby hot water faucet and leave open to allow for draining.
4.Connect a hose to the drain valve and terminate to an adequate drain.
5.OPEN the water heater drain valve to allow for tank draining.
NOTE: If the water heater is going to be shut down and drained for an extended period, the drain valve should be left open with hose connected allowing water to terminate to an adequate drain.
6.Close the drain valve.
7.Follow the instructions in the “Filling the Water Heater” section.
THERMOSTAT REMOVAL / REPLACEMENT
1.Turn “OFF” the electric power supply to the water heater.
2.Remove the outer door and fold back the insulation.
3.Lift out the tab as shown below to unclip the terminal cover from the thermostat. The terminal cover can now be removed from the thermostat.
FIGURE 13.
14