No valve or other obstruction is to be placed between the Temperature-Pressure Relief Valve and the tank. Do not connect discharge piping directly to the drain unless a 6” (15.2 cm) air gap is provided. To prevent bodily injury, hazard to life, or property damage, the relief valve must be allowed to discharge water in adequate quantities should circumstances demand. If the discharge pipe is not connected to a drain or other suitable means, the water flow may cause property damage.

CAUTION

Water Damage Hazard

Temperature-Pressure Relief Valve discharge pipe must terminate at adequate drain.

T&P Valve Discharge Pipe Requirements:

Shall not be smaller in size than the outlet pipe size of the valve, or have any reducing couplings or other restrictions.

Shall not be plugged or blocked.

Shall not be exposed to freezing temperatures.

Shall be of material listed for hot water distribution.

Shall be installed so as to allow complete drainage of both the Temperature-Pressure Relief Valve and the discharge pipe.

Must terminate a maximum of six inches above a floor drain or external to the building. In cold climates, it is recommended that the discharge pipe be terminated at an adequate drain inside the building.

Shall not have any valve or other obstruction between the relief valve and the drain.

Burn hazard.

Hot water discharge.

Keep clear of Temperature- Pressure Relief Valve discharge outlet.

The Temperature-Pressure Relief Valve must be manually operated at least twice a year. Caution should be taken to ensure that (1) no one is in front of or around the outlet of the Temperature- Pressure Relief Valve discharge line, and (2) the water manually discharged will not cause any bodily injury or property damage because the water may be extremely hot. If after manually operating the valve, it fails to completely reset and continues to release water, immediately close the cold water inlet to the water heater, follow the draining instructions in this manual, and replace the Temperature-Pressure Relief Valve with a properly rated/sized new one.

NOTE: The purpose of a Temperature-Pressure Relief Valve is to prevent excessive temperatures and pressures in the storage tank. The T&P valve is not intended for the constant relief of thermal expansion. A properly sized thermal expansion tank must be installed on all closed systems to control thermal expansion, see Closed Water Systems and Thermal Expansion on page 12.

If you do not understand these instructions or have any questions

regarding the Temperature-Pressure Relief Valve call the toll free number listed on the back cover of this manual for technical assistance.

Contaminated Air

Breathing Hazard - Carbon Monoxide Gas

Install water heater in accordance with the Instruction Manual and NFPA 54 or CAN/CSA-B149.1.

To avoid injury, combustion and ventilation air must be taken from outdoors.

Do not place chemical vapor emitting products near water heater.

Breathing carbon monoxide can cause brain damage or death. Always read and understand instruction manual.

Corrosion of the flue ways and vent system may occur if air for combustion contains certain chemical vapors. Such corrosion may result in failure and risk of asphyxiation.

Combustion air that is contaminated can greatly diminish the life span of the water heater and water heater components such as hot surface igniters and burners. Propellants of aerosol sprays, beauty shop supplies, water softener chemicals and chemicals used in dry cleaning processes that are present in the combustion, ventilation or ambient air can cause such damage.

Do not store products of this sort near the water heater. Air which is brought in contact with the water heater should not contain any of these chemicals. If necessary, uncontaminated air should be obtained from remote or outdoor sources. The limited warranty is voided when failure of water heater is due to a corrosive atmosphere. (See limited warranty for complete terms and conditions).

Air requirements

Breathing Hazard - Carbon Monoxide Gas

Install water heater in accordance with the Instruction Manual and NFPA 54 or CAN/CSA-B149.1.

To avoid injury, combustion and ventilation air must be taken from outdoors.

Do not place chemical vapor emitting products near water heater.

Breathing carbon monoxide can cause brain damage or death. Always read and understand instruction manual.

For safe operation an adequate supply of fresh uncontaminated air for combustion and ventilation must be provided.

An insufficient supply of air can cause recirculation of combustion products resulting in contamination that may be hazardous to life. Such a condition often will result in a yellow, luminous burner flame, causing sooting of the combustion chamber, burners and flue tubes and creates a risk of asphyxiation.

Do not install the water heater in a confined space unless an adequate supply of air for combustion and ventilation is brought in to that space using the methods described in the Confined Space section that follows.

14

Page 14
Image 14
Reliance Water Heaters N85390NE, N71120NE Contaminated Air, Air requirements, Valve Discharge Pipe Requirements

N71120NE, N85390NE specifications

Reliance Water Heaters has established itself as a trusted name in the water heating industry, consistently delivering high-quality products that meet the diverse needs of consumers. Among their offerings, the Reliance N71120NE and N85390NE models stand out due to their advanced features and innovative technologies.

The Reliance N71120NE is known for its efficient heating capabilities, boasting a 40-gallon capacity that is ideal for medium-sized households. This model features a durable glass-lined tank that provides exceptional resistance to rust and corrosion, ensuring longevity and durability. One of its standout characteristics is the built-in energy-saving mode, which optimizes energy consumption without compromising performance. This unit operates on electricity, making it a versatile option for various settings. Additionally, the N71120NE is designed with a temperature control thermostat, allowing users to set and maintain their desired water temperature with ease.

On the other hand, the Reliance N85390NE model offers a larger capacity of 50 gallons, making it suitable for larger families or homes with increased hot water demands. Similar to the N71120NE, this model comes with a glass-lined tank for superior protection against corrosion. One of the advanced technologies featured in the N85390NE is the High-Quality Insulation System, which minimizes heat loss and maintains water temperature efficiently. This model also includes a self-diagnostics system, providing users with real-time updates on performance and maintenance needs. The innovative anode rod in this unit extends the lifespan of the tank by sacrificially corroding instead of the tank itself.

Both models are designed with safety in mind, featuring a pressure relief valve that prevents pressure buildup, making them safe for residential use. Moreover, each unit adheres to the latest energy efficiency standards, contributing to reduced utility bills and a smaller carbon footprint.

Reliance Water Heaters emphasizes user-friendly installation and maintenance, making it easy for homeowners to enjoy the benefits of these advanced water heaters. Overall, the Reliance N71120NE and N85390NE models represent excellence in water heating technology, offering efficient, reliable, and user-friendly solutions for modern households. Choosing either of these models ensures that users can enjoy hot water on demand while benefiting from enhanced efficiency and durability.