Application Chart

Power load listings are recommendations only. If you are in doubt, try a test fastening using the next lightest power load.

Power fasteners and power loads are available in blister packs of 25 and cartons of 100.

IMPORTANT

Recommended for use with Remington® power loads and power fasteners.

If power fastener goes below the top surface of the board, use penetrating control disc (see illustration below) or wash- ered SPW-type power fasteners.

Operators and bystanders must ALWAYS wear goggles and ear protection which meet or exceed the accepted standards for adequate protection in your country. In the USA, refer to ANSI standards. In Canada, refer to CSA standards.

*Use power fastener with penetration control disc, part number 015549.

IMPORTANT

This tool is designed to use .22 caliber neck-down crimped loads, power levels 1 (gray) through 4 (yellow).

5/8"

Neck-Down Crimped

Straight Wadded

Power Load

Power Load

CAUTION: Do not use any load other than the .22 caliber neck-down crimped load. Other types of loads will cause load-ejection problems.

.22 CALIBER Type A, neck-down crimp loads for powder actuated tools

 

 

Load

 

Color Code

 

Stock

Level

Load

Case

 

 

Number

Number

Strength

Body

Head

 

 

 

 

 

 

 

A22C1

1

light

brass

Gray

 

A22C2

2

medium

brass

Brown

 

A22C3

3

heavy

brass

Green

 

A22C4

4

extra heavy

brass

Yellow

 

 

 

 

 

 

119586

21

Page 21
Image 21
Remington r300 operating instructions Load Color Code Stock, Case Number, Body Head