HD151TS207SS
Rev.1.00, Apr.25.2003, page 27 of 38
Absolute Maximum Ratings
Item Symbol Ratings Unit Conditions
Supply voltage VDD –0.5 to 4.6 V
Input voltage VI–0.5 to 4.6 V
Output voltage *1 VO–0.5 to VDD
+0.5 V
Input clamp current IIK –50 mA VI < 0
Output clamp current IOK –50 mA VO < 0
Continuous output current IO±50 mA VO = 0 to VDD
Maximum power dissipation
at Ta = 55°C (in still air) 0.7 W
Storage temperature Tstg –65 to +150 °C
Notes: Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage
to the device. These are stress ratings only, and functional operation of the device at these or
any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute maximum rated conditions for extended periods may affect device
reliability.
1. The input and output negative voltage ratings may be exceeded if the input and output cl amp
current ratings are observed.
Recommended Operating Conditions
Item Symbol Min Typ Max Unit Conditions
Supply voltage VDD 3.135 3.3 3.465 V
Supply voltage VDDA 3.135 3.3 3.465 V
DC input signal voltage –0.3 VDD+0.3 V
High level input voltage VIH 2.0 VDD+0.3 V
Low level input voltage VIL –0.3 — 0.8 V
Operating temperature Ta0—70°C