HD151TS207SS
Rev.1.00, Apr.25.2003, page 28 of 38
DC Electrical Characteristics / Serial Input Port
Ta = 0°C to 70°C, VDD = 3.3 V
Item Symbol Min Typ *1Max Unit Test Conditions
Input Low Voltage VIL 0.8 V
Input High Voltage VIH 2.0 V
Input Current II–50 +50 µA VI = 0 V or 3.465 V,
VDD = 3.465 V
Input capacitance CI10 pF SDATA & SCLK
Note: 1. For conditions shown as Min or Max, use the appropriate value specified under recommended
operating conditions.
AC Electrical Characteristics / Serial Input port
Ta = 0°C to 70°C, VDD = 3.3 V
Item Symbol Min Typ Max Unit Test Conditions Notes
SCLK Frequency FSCLK 100 kHz Normal Mode
Start Hold Time tSTHD 4.0 µs
SCLK Low Time tLOW 4.7 µs
SCLK High Time tHIGH 4.0 µs
Data Setup Time tDSU 250 ns
Data Hold Time tDHD 300 ns
Stop Setup Time tSTSU 4.0 µs
BUS Free Time between
Stop & Start Condition tSPF 4.7 µs