Rev.1.00    2007.11.1 
REC10B0002-0100 
90
(Operating 
states set) 
Specify one from { RAPI_AD_ON, RAPI_AD_OFF }. The default value is 
RAPI_AD_OFF. 
(Conversion 
method) 
Specify one from { RAPI_WITH_SAMPLE_HOLD, 
RAPI_WITHOUT_SAMPLE_HOLD }. The default value is 
RAPI_WITHOUT_SAMPLE_HOLD. 
(Trigger)  Specify one from { RAPI_SOFTWARE_TRIGGER, 
RAPI_EXTERNAL_TRIGGER }. The default value is 
RAPI_SOFTWARE_TRIGGER. 
(External 
Op-Amp 
Connection) 
Specify one from { RAPI_ANEX_UNUSED, RAPI_EXTERNAL_OP_AMP }. 
The default value is RAPI_ANEX_UNUSED. 
�� Specifiable definition values when repeat sweep mode 1 is used 
(RAPI_REPEAT_SWEEP1 specified) 
(Input pin)  Specify one from { RAPI_P0_GROUP, RAPI_P10_GROUP, 
RAPI_P2_GROUP }. The default value is RAPI_P10_GROUP. 
(Operating 
frequency) 
Specify one from { RAPI_FAD, RAPI_FAD2, RAPI_FAD3, RAPI_FAD4, 
RAPI_FAD6, RAPI_FAD12 }. The default value is RAPI_FAD4. 
(Resolution)  Specify one from { RAPI_10BIT, RAPI_8BIT }. The default value is 
RAPI_8BIT. 
(Operating 
states set) 
Specify one from { RAPI_AD_ON, RAPI_AD_OFF }. The default value is 
RAPI_AD_OFF. 
(Conversion 
method) 
Specify one from { RAPI_WITH_SAMPLE_HOLD, 
RAPI_WITHOUT_SAMPLE_HOLD }.  
The default value is RAPI_WITHOUT_SAMPLE_HOLD. 
(Trigger)  Specify one from { RAPI_SOFTWARE_TRIGGER, 
RAPI_EXTERNAL_TRIGGER }.   
The default value is RAPI_SOFTWARE_TRIGGER. 
(External 
Op-Amp 
Connection) 
Specify one from { RAPI_ANEX_UNUSED, RAPI_EXTERNAL_OP_AMP }. 
The default value is RAPI_ANEX_UNUSED. 
 [data2] 
   The set value differs with the A/D conversion mode used. 
One-shot mode  Specify 1. 
Repeat mode   
Single sweep mode  Specify 2, 4, 6, or 8. 
Repeat sweep mode 0   
Repeat sweep mode1  Specify 1, 2, 3, or 4. 
 [data3] 
Specify the interrupt priority level (0–7) to be set in the interrupt control register. 
Return value   
If A/D converter was successfully set, RAPI_TRUE is returned; if failed, RAPI_FALSE 
is returned. 
Functionality   A/D converter 
Reference   __EnableADC, __DestroyADC, __GetADC, __GetADCAll