VPAP AUTO FEATURES SUMMARY

Modes of operation

VAuto

S (Spontaneous)

CPAP

Product features

Simplified standard setting menu

Vsyncautomatic leak management

TiControl(Ti max/min)

Adjustable breath trigger/cycle

Adjustable exhalation comfort

12V DC input (via converter)

Auto-adjusting bilevel pressures

Compact S8 design

AutoSet technology

Smooth pressure delivery

Heated humidification

• Optional, fully integrated

Data storage

Usage and Treatment Summary (day, week, month, six-month, year)

Usage profile

Summary data storage

Detailed data storage

Remote settings adjustment

Data transfer

Direct download to PC

ResLink via SmartMedia card

ResScan Data Card

TECHNICAL SPECIFICATIONS

Performance

Operating pressure range: 3 to 20 cm H2O

Maximum single fault pressure: 30 cm H2O

Dynamic pressure characteristics

VAuto mode: 4 to 20 cm H2O (Pressure support: 0 to 10 cm H2O)

S mode: IPAP: 5 to 20 cm H2O; EPAP: 3 to 20 cm H2O

CPAP mode: 4 to 20 cm H2O

Sound pressure level

< 24 dB (tested in accordance with the requirements of ISO 17510-1:2002)

Data storage

Data includes usage, leak, pressure, AHI, AI, tidal volume, respiratory rate and minute ventilation

Via LCD menu: 365 sessions of summary data

Via ResLink: 365 sessions of summary data, 30 sessions of detailed data

Via ResScan Data Card: 180 sessions of summary data, two sessions of detailed data

Dimensions (L x W x H): 4.4" x 6.5" x 5.7" (112 mm x 164 mm x 145 mm)

Weight: 2.9 lb (1.3 kg)

Power supply

Input range 100–240V, 50–60Hz, 40VA (typical power consumption), < 100VA (maximum power consumption)

Environmental conditions

Operating temperature: 41°F to 97°F (+5°C to +36°C)

Operating humidity: 10–95% non-condensing

Electromagnetic Compatibility

Product complies with all applicable electromagnetic compatibility requirements (EMC) for residential, commercial and light industry environments according to IEC 60601-1-2.

Air filter

Two-layered, powder-bonded, polyester non-woven fiber

IEC 60601-1 classification

Class II (double insulated), Type CF

Note: The manufacturer reserves the right to change these specifications without notice.

PRODUCT CODES

VPAP Auto

26301

HumidAire 3i

33906

ResMed Corp Poway, CA, USA +1 858 746 2400 or 1 800 424 0737 (toll free), ResMed Ltd Bella Vista, NSW, Australia +61 (2) 8884 1000 or 1 800 658 189 (toll free). Offices in Austria, Brazil, Finland, France, Germany, Hong Kong, Japan, Malaysia, Mexico, Netherlands, New Zealand, Singapore, Spain, Sweden, Switzerland, United Kingdom (see website for details). ResControl, ResLink, ResScan, ResTraxx, S8, TiControl, VPAP Adapt SV and Vsync are trademarks of ResMed Ltd. AutoSet, HumidAire and VPAP are trademarks of ResMed Ltd and registered in U.S. Patent and Trademark Office. ©2007 ResMed. 1012117/2 07 12