be
Using with a Solo Executive Multi-channel System
The Revolabs Solo™ Single Channel Wearable Microphone can be paired to a Solo Executive Multi- channel Wireless Microphone System for users who wish to have a single microphone to use in both the office and in the conference room. This is accomplished by pairing the Single Channel Wearable Microphone to the Executive
Charging the Batteries
To charge the batteries place the Microphone into the Single Channel Charger Base. During charging, the Microphone status LED indicator changes from solid RED to solid GREEN as charging completes. The Charger Base status indicator remains off during charging. The Microphone is always muted while in the Charger Base. The battery charges from fully depleted to fully charged in approximately two hours, however, it is
Note: A fully charged battery provides approximately 8 hours of talk time.
When to Charge
Before using the Microphone for the first time, charge for 8 hours or overnight in the Charger Base (until microphone LED turns solid GREEN).
When the Microphone LED begins flashing alternating YELLOW and RED or YELLOW and GREEN, the battery needs recharging. Over time (years), batteries gradually wear down and require charging after a shorter period of use. This is normal.
Important: The Lithium Polymer rechargeable battery that powers the Microphone is not user serviceable. Please see the Revolabs website (www.revolabs.com) for information regarding battery replacement and proper disposal procedures. Warning: Exposing the batteries to fire may result in an explosion.
Setting the Broadcast Power Level
In confined settings where multiple Solo Executive Single Channel systems are used, or where audio interference is likely, it may be necessary to reduce the broadcast power levels.
The broadcast power level between the Microphone and Charger Base can be set to the following three levels.
•Highest power level – 60 feet (25M) maximum operating distance between Microphone and Charger Base (default setting).
•Medium power level – 20 feet (7M) maximum operating distance between Microphone and Charger Base.
•Lowest power level – 6 feet (2M) maximum operating distance between Microphone and Charger Base.
To set the broadcast power level:
Press and hold the Mute button while plugging the USB cable into the Charger Base.
The status LED on the Charger Base will display a sequence of flashes, during which it will flash once, then twice, then three times, where:
1 GREEN flash = full power
2 GREEN flashes = medium power
3 GREEN flashes = low power.
This cycle will repeat 10 times. During any of the cycles, simply release the Mute button immediately after the desired power indication, to set the