M219 room amplifier | Re:connect |
M219 local inputs |
|
See description: [1] | LOCAL IN 1 2 3 |
Number of local
inputs
0
1
2
3
DIL switch | DIL switch | DIL position |
| |
4 | 5 |
|
|
|
Off | Off | 4 | 5 |
|
|
|
| ||
Off | On | 4 | 5 |
|
|
|
| ||
On | Off | 4 | 5 |
|
|
|
| ||
On | On | 4 | 5 |
|
|
|
|
M219 addressing
If you want to control each M219 individually, to use the alarm function of the M51 Timer, for example, it is necessary to assign each M219 its own address. The maximum number of M219s is limited to 8 per zone.
All M219s must have different addresses within one zone as otherwise there may be communication problems.
The revisal of a correct addressing is made in the Setup menu of the
M51, category Multiroom / Version. All attached devices (M219 and/or M217) must be listed in the respective zone.
Address
1
2
3
4
5
6
7
8
DIL switch | DIL switch | DIL switch | DIL position |
| ||
6 | 7 | 8 |
|
|
|
|
Off | Off | Off | 6 | 7 | 8 |
|
|
|
|
| |||
Off | Off | On | 6 | 7 | 8 |
|
|
|
|
| |||
Off | On | Off | 6 | 7 | 8 |
|
|
|
|
| |||
Off | On | On | 6 | 7 | 8 |
|
|
|
|
| |||
On | Off | Off | 6 | 7 | 8 |
|
|
|
|
| |||
On | Off | On | 6 | 7 | 8 |
|
|
|
|
| |||
On | On | Off | 6 | 7 | 8 |
|
|
|
|
| |||
On | On | On | 6 | 7 | 8 |
|
|
|
|
|
12