Rheem 72V30-2, 72V20-1, AP10414-9 Insulation Blankets, Hot and Cold Pipe Insulation Installation

Models: 72V40-2 AP10414-9 72V52-2 72V20-1 72V30-2

1 20
Download 20 pages 22.21 Kb
Page 10
Image 10

Installing the water heater.

WARNING: If local codes require external application of insulation blanket kits the manufacturer’s instructions included with the kit must be carefully followed.

Insulation Blankets

Insulation blankets, available to the general public, for external use on electric water heaters are not necessary. The purpose of an insulation blanket is to reduce the standby heat loss encountered with storage tank heaters. This water heater meets or exceeds the National Appliance Energy Conservation Act standards with respect to insulation and standby loss requirements making an insulation blanket unnecessary.

The manufacturer’s warranty does not cover any damage or defect caused by installation, attachment or use of any type of energy saving or other unapproved devices (other than those authorized by the manufacturer) into, onto or in conjunction with the water heater. The use of unauthorized energy saving devices may shorten the life of the water heater and may endanger life and property.

The manufacturer disclaims any responsibility for such loss or injury resulting from the use of such unauthorized devices.

CAUTION: If local codes require the application of an external insulation blanket to this water heater, pay careful attention to the following so as not to restrict the proper function and operation of the water heater:

zDo not cover the operating or warning labels attached to the water heater or attempt to relocate them on the exterior of insulation blanket.

zDo not apply insulation to the top of the water heater. this could interfere with the safe operation of the electrical junction box.

zDo not cover the jacket access panel(s) to the thermostat(s) and heating element(s), or pressure and temperature relief valve.

zInspect the insulation blanket frequently.

Hot and Cold Pipe Insulation Installation

HOT

 

 

IL

ER

 

 

F

E

 

 

 

 

 

 

 

L A

V

 

 

 

EV

 

 

 

 

 

 

LD

 

 

 

 

CO

 

 

 

 

 

HOT

 

L E

R

 

 

E I

 

 

F

 

 

L A

V

 

 

EV

 

 

COLD

Typical vertical piping

Typical horizontal piping

Typical side piping

arrangement

arrangement

arrangement

For increased energy efficiency, some water heaters have been supplied with two 24” sections of pipe insulation.

Please install the insulation, according to the illustrations above, that best meets your requirements.

10

Page 10
Image 10
Rheem 72V30-2, 72V20-1, AP10414-9, 72V40-2, 72V52-2 Insulation Blankets, Hot and Cold Pipe Insulation Installation