IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING.

WARNING!

WATER TEMPERATURE ADJUSTMENT

Safety and energy conservation are factors to be considered when selecting the water temperature setting of water heater’s thermostat. Water temperatures above 125°F can cause severe burns or death from scalding. Be sure to read and follow the warnings outlined on the label pictured below. This label is also located on the water heater near the thermostat access panel.

!D A N G E R

HOT

BURN

Water temperature over 125°F can cause severe burns instantly or death from scalds.

Children, disabled and elderly are at highest risk of being scalded.

See instruction manual before setting temperature at water heater.

Feel water before bathing or showering.

Temperature limiting valves are available, see manual.

NOTICE: Mixing valves are available for reducing point of use water temperature by mixing hot and cold water in branch water lines. Contact a licensed plumber or the local plumbing authority for further information.

Time/Temperature Relationship in Scalds

Temperature

Time To Produce a Serious Burn

120°F

More than 5 minutes

125°F

11/2 to 2 minutes

130°F

About 30 seconds

135°F

About 10 seconds

140°F

Less than 5 seconds

145°F

Less than 3 seconds

150°F

About 11/2 seconds

155°F

About 1 second

Table courtesy of Shriners Burn Institute

The chart shown above may be used as a guide

in determining the proper water temperature for your home.

NOTICE: Households with small children, disabled,

or elderly persons may require a 120°F or lower thermostat setting to prevent contact with “HOT” water.

The temperature of the water in the heater is regulated by the adjustable surface mounted thermostat(s) located behind the jacket access panel(s). Dual element heaters have two thermostats. To comply with safety regulations the thermostat(s) were set at 120°F before the water heater was shipped from the factory.

 

 

 

The illustration at the left

Reset button

SE

S

shows the temperature

ER

T E

 

 

T

R

 

 

 

E

 

 

 

 

adjustment dial used for

 

 

 

setting the water

Thermostat

 

 

temperature.

dial pointer

 

 

Refer to the Operating

 

 

 

 

150°F

90°F

Instructions in this

 

125°F

manual for detailed

 

BEFORE

 

TURN OFF

 

Thermostat

POWER

instructions in how to

SERVICING

protective

 

 

adjust the thermostat(s).

cover

 

 

 

DANGER: Hotter water increases the potential for Hot Water SCALDS.

3

Page 3
Image 3
Rheem 72V40-2, 72V30-2, 72V20-1, AP10414-9, 72V52-2 installation instructions N G E R