SYSTEMS PERFORMANCE—RJNA- SERIES

COOLING PERFORMANCE DATA—RJNA-A036

ENTERING INDOOR AIR @ 80°F [26.7°C] dbE

 

wbE

 

71°F [21.7°C]

 

 

67°F [19.4°C]

 

 

63°F [17.2°C]

 

 

 

CFM [L/s]

1440 [680]

1200 [566]

960 [453]

1440 [680]

1200 [566]

960 [453]

1440 [680]

1200 [566]

960 [453]

 

 

DR

.16

.13

.08

.16

.13

.08

.16

.13

.08

 

 

 

75

Total BTUH [kW]

46.4 [13.60]

44.8 [13.13]

43.1 [12.63]

43.4 [12.72]

41.9 [12.28]

40.4 [11.84]

41.1 [12.05]

39.7 [11.63]

38.2 [11.20]

 

 

 

Sens BTUH [kW]

27.9

[8.18]

25.5

[7.47]

23.1

[6.77]

33.5

[9.82]

30.6

[8.97]

27.7

[8.12]

34.8 [10.20]

31.8

[9.32]

28.8

[8.44]

 

 

 

[23.9]

 

O

 

Power

 

2.2

 

2.2

 

2.2

 

2.2

 

2.2

 

2.1

 

2.2

 

2.2

 

2.1

 

 

 

Total BTUH [kW]

45.5 [13.33]

43.9 [12.87]

42.3 [12.40]

42.6 [12.48]

41.1 [12.05]

39.6 [11.61]

40.2 [11.78]

38.8 [11.37]

37.4 [10.96]

 

 

 

 

U

80

 

T

Sens BTUH [kW]

27.3

[8.00]

25.0

[7.33]

22.6

[6.62]

32.9

[9.64]

30.0

[8.79]

27.2

[7.97]

34.2 [10.02]

31.3

[9.17]

28.3

[8.29]

 

[26.7]

 

D

Power

 

2.3

 

2.3

 

2.3

 

2.3

 

2.3

 

2.3

 

2.3

 

2.3

 

2.3

 

O

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

O

85

Total BTUH [kW]

44.5 [13.04]

42.9 [12.57]

41.3 [12.10]

41.5 [12.16]

40.0 [11.72]

38.6 [11.31]

39.2 [11.49]

37.8 [11.08]

36.4 [10.67]

 

R

Sens BTUH [kW]

26.7

[7.83]

24.4

[7.15]

22.1

[6.48]

32.3

[9.47]

29.5

[8.65]

26.8

[7.85]

33.6

[9.85]

30.7

[9.00]

27.9

[8.18]

 

 

 

[29.4]

 

D

Power

 

2.5

 

2.4

 

2.4

 

2.4

 

2.4

 

2.4

 

2.4

 

2.4

 

2.4

 

R

 

90

Total BTUH [kW]

43.3 [12.69]

41.7 [12.22]

40.2 [11.78]

40.3 [11.81]

38.9 [11.40]

37.5 [10.99]

38.0 [11.14]

36.6 [10.73]

35.3 [10.35]

 

Y

 

Sens BTUH [kW]

26.1

[7.65]

23.9

[7.00]

21.7

[6.36]

31.7

[9.29]

29.0

[8.50]

26.3

[7.71]

33.0

[9.67]

30.2

[8.85]

27.4

[8.03]

 

 

 

[32.2]

 

B

Power

 

2.6

 

2.5

 

2.5

 

2.6

 

2.5

 

2.5

 

2.6

 

2.5

 

2.5

 

U

 

 

Total BTUH [kW]

42.0 [12.31]

40.5 [11.87]

39.0 [11.43]

39.0 [11.43]

37.6 [11.02]

36.3 [10.64]

36.7 [10.76]

35.4 [10.37]

34.1 [9.99]

 

 

 

 

L

95

 

B

Sens BTUH [kW]

25.6

[7.50]

23.4

[6.86]

21.2

[6.21]

31.1

[9.11]

28.5

[8.35]

25.8

[7.56]

32.4

[9.50]

29.7

[8.70]

26.9 [7.88]

 

[35]

 

 

 

Power

 

2.7

 

2.6

 

2.6

 

2.7

 

2.6

 

2.6

 

2.7

 

2.6

 

2.6

 

T

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Total BTUH [kW]

40.7 [11.93]

39.3 [11.52]

37.8 [11.08]

37.7 [11.05]

36.4 [10.67]

35.1 [10.29]

35.4 [10.37]

34.2 [10.02]

32.9 [9.64]

 

E

100

 

M

Sens BTUH [kW]

25.0

[7.33]

22.8

[6.68]

20.7

[6.07]

30.5

[8.94]

27.9

[8.18]

25.3

[7.41]

31.9

[9.35]

29.1

[8.53]

26.4 [7.74]

 

P

[37.8]

 

E

 

Power

 

2.8

 

2.8

 

2.7

 

2.8

 

2.7

 

2.7

 

2.8

 

2.7

 

2.7

 

R

 

105

Total BTUH [kW]

39.5 [11.58]

38.1 [11.17]

36.7 [10.76]

36.5 [10.70]

35.2 [10.32]

33.9 [9.94]

34.2 [10.02]

33.0 [9.67]

31.8 [9.32]

 

A

Sens BTUH [kW]

24.4

[7.15]

22.3

[6.54]

20.2

[5.92]

30.0

[8.79]

27.4

[8.03]

24.8 [7.27]

31.3

[9.17]

28.6 [8.38]

25.9 [7.59]

 

T

[40.6]

 

U

Power

 

2.9

 

2.9

 

2.8

 

2.9

 

2.9

 

2.8

 

2.9

 

2.9

 

2.8

 

R

 

 

Total BTUH [kW]

38.4 [11.25]

37.0 [10.84]

35.7 [10.46]

35.4 [10.37]

34.2 [10.02]

32.9 [9.64]

33.1 [9.70]

31.9 [9.35]

30.8 [9.03]

 

 

 

 

E

110

 

Sens BTUH [kW]

23.8

[6.98]

21.8

[6.39]

19.7

[5.77]

29.3

[8.59]

26.8

[7.85]

24.3 [7.12]

30.7 [9.00]

28.0 [8.21]

25.4 [7.44]

 

°F

[43.3]

 

Power

 

3.0

 

3.0

 

2.9

 

3.0

 

3.0

 

2.9

 

3.0

 

3.0

 

2.9

 

[°C]

 

 

Total BTUH [kW]

37.5 [10.99]

36.1 [10.58]

34.8 [10.20]

34.5 [10.11]

33.3 [9.76]

32.1 [9.41]

32.2 [9.44]

31.0 [9.09]

29.9 [8.76]

 

 

115

 

 

 

 

 

 

Sens BTUH [kW]

23.2

[6.80]

21.2

[6.21]

19.2

[5.63]

28.7

[8.41]

26.3 [7.71]

23.8 [6.98]

30.0 [8.79]

27.5 [8.06]

24.9 [7.30]

 

 

 

[46.1]

 

 

 

Power

 

3.1

 

3.1

 

3.0

 

3.1

 

3.1

 

3.0

 

3.1

 

3.1

 

3.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DR —Depression ratio dbE —Entering air dry bulb wbE—Entering air wet bulb

Total —Total capacity x 1000 BTUH Sens —Sensible capacity x 1000 BTUH Power—KW input

NOTES:

When the entering air dry bulb is other than 80°F [27°C], adjust the sensible capacity from the table by adding [1.10 x CFM x (1 – DR) x (dbE – 80)].

HEATING PERFORMANCE DATA—RJNA-A036

 

IDB

 

60°F [15.5°C]

 

 

70°F [21.1°C]

 

 

80°F [26.7°C]

 

 

 

CFM [L/s]

1440 [680]

1200 [566]

960 [453]

1440 [680]

1200 [566]

960 [453]

1440 [680]

1200 [566]

960 [453]

 

 

O

 

0

Total BTUH [kW]

8.9

[2.61]

8.7

[2.55]

8.6

[2.52]

7.0

[2.05]

6.9

[2.02]

6.8

[1.99]

5.3

[1.55]

5.2

[1.52]

5.1

[1.49]

 

 

 

[-17.8]

Power

 

2.1

 

2.1

 

2.2

 

2.3

 

2.4

 

2.4

2.6

2.6

2.7

 

 

U

 

 

 

 

 

 

 

 

 

T

 

5

Total BTUH [kW]

12.2

[3.58]

12.0

[3.52]

11.9

[3.49]

10.4

[3.05]

10.2

[2.99]

10.1

[2.96]

8.6

[2.52]

8.5

[2.49]

8.4

[2.46]

 

 

D

 

[26.7]

Power

 

2.1

 

2.2

 

2.2

 

2.4

 

2.4

 

2.5

2.6

2.7

2.7

 

 

O

 

 

 

 

 

 

 

 

 

O

 

10

Total BTUH [kW]

15.5

[4.54]

15.3

[4.48]

15.1

[4.43]

13.6

[3.99]

13.5

[3.96]

13.3

[3.90]

11.9

[3.49]

11.8

[3.46]

11.6

[3.40]

 

 

R

 

[-12.2]

Power

 

2.2

 

2.2

 

2.3

 

2.4

 

2.5

 

2.5

2.6

2.7

2.8

 

 

 

 

 

 

 

 

 

 

 

 

D

 

15

Total BTUH [kW]

18.7

[5.48]

18.5

[5.42]

18.2

[5.33]

16.9

[4.95]

16.6

[4.86]

16.4

[4.81]

15.1

[4.43]

14.9

[4.37]

14.7

[4.31]

 

 

R

 

[32.2]

Power

 

2.2

 

2.3

 

2.3

 

2.4

 

2.5

 

2.6

2.7

2.8

2.8

 

 

Y

 

 

 

 

 

 

 

 

 

B

 

20

Total BTUH [kW]

21.8

[6.39]

21.5

[6.30]

21.2

[6.21]

20.0

[5.86]

19.7

[5.77]

19.4

[5.69]

18.3

[5.36]

18.0

[5.28]

17.7

[5.19]

 

 

 

[-6.6]

Power

 

2.2

 

2.3

 

2.4

 

2.5

 

2.5

 

2.6

2.7

2.8

2.9

 

 

U

 

 

 

 

 

 

 

 

 

L

 

25

Total BTUH [kW]

24.8

[7.27]

24.5

[7.18]

24.1

[7.06]

23.0

[6.74]

22.7

[6.65]

22.3

[6.54]

21.3

[6.24]

21.0

[6.15]

20.7

[6.07]

 

 

B

 

[37.8]

Power

 

2.3

 

2.3

 

2.4

 

2.5

 

2.6

 

2.6

2.8

2.8

2.9

 

 

 

 

 

 

 

 

 

 

 

 

T

 

30

Total BTUH [kW]

27.7

[8.12]

27.3

[8.00]

26.9

[7.88]

25.9

[7.59]

25.5

[7.47]

25.1

[7.36]

24.1

[7.06]

23.8

[6.98]

23.5

[6.89]

 

 

E

 

[-1.1]

Power

 

2.3

 

2.4

 

2.4

 

2.5

 

2.6

 

2.7

2.8

2.9

2.9

 

 

M

 

 

 

 

 

 

 

 

 

P

 

35

Total BTUH [kW]

30.5

[8.94]

30.0

[8.79]

29.6

[8.67]

28.6

[8.38]

28.2

[8.26]

27.8

[8.15]

26.9

[7.88]

26.5

[7.77]

26.1

[7.65]

 

 

E

 

[43.3]

Power

 

2.4

 

2.4

 

2.5

 

2.6

 

2.6

 

2.7

2.8

2.9

3.0

 

 

R

 

 

 

 

 

 

 

 

 

A

 

40

Total BTUH [kW]

33.0

[9.67]

32.6

[9.55]

32.1

[9.41]

31.2

[9.14]

30.7

[9.00]

30.3

[8.88]

29.5

[8.65]

29.0

[8.50]

28.6

[8.38]

 

 

T

 

[4.4]

Power

 

2.4

 

2.5

 

2.5

 

2.6

 

2.7

 

2.7

2.9

2.9

3.0

 

 

U

 

 

 

 

 

 

 

 

 

R

 

45

Total BTUH [kW]

35.4

[10.37]

34.9

[10.23]

34.4

[10.08]

33.6

[9.85]

33.1

[9.70]

32.6

[9.55]

31.9

[9.35]

31.4

[9.20]

31.0

[9.09]

 

 

E

 

[46.1]

Power

 

2.4

 

2.5

 

2.6

 

2.7

 

2.7

 

2.8

2.9

3.0

3.1

 

 

 

 

 

 

 

 

 

 

 

 

°F

 

50

Total BTUH [kW]

37.6

[11.02]

37.1

[10.87]

36.6

[10.73]

35.8

[10.49]

35.3

[10.35]

34.8

[10.20]

34.1

[9.99]

33.6

[9.85]

33.1

[9.70]

 

 

[°C]

 

[10]

Power

 

2.5

 

2.5

 

2.6

 

2.7

 

2.8

 

2.8

2.9

3.0

3.1

 

 

 

 

 

 

 

 

 

 

 

IDB—Indoor air dry bulb

 

 

 

 

 

 

 

 

 

 

 

 

[

] Designates Metric Conversions

15