ACCESSORIES—RJNA- SERIES

Roofcurb Adapters

Old Models

MEDIUM CABINET (3 TON [11 kW])

(-)SNC, (-)SND, (-)SNE (-)RGE, (-)RGF, (-)RGG (-)PNC, (-)PND

LARGE CABINET (3-3.5 TON [11-12 kW])

(-)RGE, (-)RGF, (-)RGG, (-)RGH (3 TON [11 kW])

EXTRA LARGE CABINET (3.5-5 TON [12-18 kW])

(-)SNC, (-)SND, (-)SNE (-)RGE, (-)RGF,

(-)RGG (4-5 TON [14-18 kW]) (-)PNC, (-)PND, (-)RGH (3.5, 4 TON [12-14 kW])

OLD CURB MODEL ROOFCURB ADAPTER

NEW MODEL

RXPA-CA21 (1)

21 SERIESRXRX-BBCDB21 RXRA-DB21 (2)

RXPA-CA22 (1)

22 SERIESRXRX-BBCDB22 RXRA-DB22 (2)

RJNA

RXPA-CA23 (1)

23 SERIESRXRX-BBCDB23 RXRA-DB23 (2)

(1) SLOPE TYPE (2) FULL PERIMETER TYPE

Field Installed Resistance Heater Kits

Electric Heater Kits are designed for field installation using either single-point power wiring or dual circuit wiring. Low voltage plugs are provided to allow for quick connection to the unit. Removing a block- off panel on the unit allows the heater elements to be inserted into the supply air down stream from the indoor coil and supply air blower.

[ ] Designates Metric Conversions

Model Number Identifier:

R X J J — A 15 C

Electrical Designation

J = 208-230 V, 1 PH, 60 Hz

C = 208-230 V, 3 PH, 60 Hz

D = 460 V, 3 PH, 60 Hz

Nominal Heater kW

 

 

06 = 6 kW

15

= 15 kW

10

= 10 kW

20

= 20 kW

11

= 11 kW *

21

= 21 kW *

12

= 12 kW

24

= 24 kW

* Canadian Models Only

Design Series

A = Initial Design

Accessory Designation

J = Electric Heater

Accessory Classification

J = Package Heat Pump

X = Accessory

R = Trade Name

35