INSTALLATION – SOLAR STORAGE TANK
THIS WATER HEATER IS FOR OUTDOOR INSTALLATION ONLY.
THIS WATER HEATER IS NOT SUITABLE FOR POOL HEATING.
Check the water heater is suitable for the gas type available.
(refer to the rating label on the water heater)
The system is suitable for installation with Rheem NPT 200 solar collectors.
The system is not suitable for installation above 400 metres altitude.
The system when installed in areas subject to freeze conditions must be
installed with the solar hot and solar cold pipes fully insulated with closed cell
polymer insulation (minimum thickness 13 mm) to offer protection against
freeze damage. Freeze conditions occur below 6°C. The system has NO
WARRANTY for freeze damage when installed above 400 metres altitude or if
the solar hot and solar cold pipes are uninsulated (refer to “Warranty
Exclusions” on page 59 and to “Warning: Plumber Be Aware” on page 38).
Thicker insulation may be required to comply with the requirements of
AS/NZS 3500.4.
SOLAR WATER HEATER STORAGE TANK LOCATION
The solar storage tank should be installed close to the most frequently used
outlet and its position chosen with safety and service in mind. Make sure
people (particularly children) will not touch the flue outlet. The flue terminal
must be clear of obstructions and shrubbery.
Consideration must also be given to the position of the solar storage tank in
relation to the solar collectors. There are limitations on the maximum length of
the solar hot and solar cold pipes between the solar storage tank and the solar
collectors. Refer to “Solar Collector Location” on page 36 and to “Pipe Lengths”
on page 37.
Clearance must be allowed for
servicing of the solar storage tank. The
solar storage tank must be accessible
without the use of a ladder or scaffold.
Make sure the temperature pressure
relief valve lever is accessible and the
access covers and burner can be
removed for service.
If possible leave headroom of one
water heater length so the anode can
be inspected or replaced. Remember
you may have to remove the entire
solar storage tank later for servicing.
26