RIDGID BW-1790 dimensions Single-Stage, Two-WayValve, Service Notes for H-18

Models: BW-1790

1 1
Download 1 pages 40.9 Kb
Page 1
Image 1
Hydraulic Hand Pump, H-18

Hydraulic Hand Pump, H-18

Single-Stage, Two-Way Valve

 

4

 

3

1

 

5

6

 

 

 

2

1

7

12

 

 

13

 

 

 

8

 

22

 

9

14

 

 

15

 

21

 

 

 

 

10

16

 

20

 

17

19

 

11

17

 

23

 

 

18

 

 

26

 

 

 

 

27

28

 

 

20

 

 

 

 

30

29

17

 

31

 

32 33

 

35

 

36

RESERVOIR CAPACITY

Proper Oil Fill: 18.6 Cu. In. = 10.5 Ozs. Fill to between lines inside reservoir.

24

23

34

25

High Pressure

Relief (See

Service Notes)

NOTE: Order parts by Catalog Number only. DO NOT order by Reference Number.

Ref. Catalog

No. No. Description

24542 H-18 Hand Pump

1

24497*

Snap Ring (6)

2

24492

Pin

3

24202

Pin

4

24222

Handle Head

5

24502

Handle

6

24272

Hand Grip

7

24487

Lever Crank

8

24127

Piston

924132 Packing Nut

1024137* Back-up Ring

1124142* O-Ring

1224177 Spring Stop Bolt

1324147* Copper Washer

1424182* Spring

1524187* Steel Ball (6 mm)

1624192* Spring

1724152* Steel Ball (3) (4.8 mm)

1824227* Copper Washer

19

24162

Valve Stem

NOTE: All components are METRIC dimensions.

Ref.

Catalog

Description

No.

No.

20

24157*

O-Ring (2)

2124167 Valve Guide

2224172 Knob

23

24507

O-Ring (2)

24

24232

Reservoir

2524237 Reservoir Cap

2621847 Hydraulic Hose, 3 ft.

2724207 Pin

28

24122

Pump Body

29

24217

Elbow, 45 Deg., 3/8″ NPTF

30

24247

Valve Body

31

24252

Ball Guide

32

24257

Spring

33

24262

Jam Nut

3424267 Adjusting Plug

3524197 Intake Tube w/Filter

3624107 Hose Half Coupler

Following items not shown:

26032* Decal, Trade Name

26067 Repair Kit (includes * items)

Items marked with an asterisk (*) are included in the Repair Kit. †See Service Notes.

Service Notes for H-18

HIGH PRESSURE RELIEF VALVE SETTING

The High Pressure Relief Valve on this pump is factory preset at 9,400 to 10,500 PSI. The setting can be checked or reset as follows: A. Attach a 15,000 PSI gauge to outlet port of pump.

B. Operate pump cautiously to build pressure while watching gauge. C. If maximum pressure exceeds 10,500 PSI:

1.Stop pumping and open release valve.

2.Turn adjusting plug, Ref. 34, counterclockwise 1/2 turn and retest.

D.If maximum pressure is less than 9,400:

1.Turn adjusting plug clockwise 118 turn and retest.

E.Continue Step “C” or “D” until specified range is achieved. Lock in place with jam nut, Ref. 33.

Ridge Tool Company/Elyria, Ohio, U.S.A.

62

Page 1
Image 1
RIDGID BW-1790 dimensions Single-Stage, Two-WayValve, Service Notes for H-18, Hydraulic Hand Pump, H-18