Rinnai KA2530FFUD manual Controller Controller Cable Safety Devices, Clearances from Combustibles

Models: KA2530FFUD

1 2
Download 2 pages 20.02 Kb
Page 2
Image 2
Controller

Controller

Controller Cable Safety Devices

RC80i (KA2530FFUD)

MC-91-1US (included)

Deluxe controller: MC-100V-1US (optional)

Bathroom controller: BC-100V-1US (optional)

MCC-91-1US (for commercial applications)

Non-polarized two-core cable, minimum 22 AWG

Flame failure - Flame Rod

Remaining flame (OHS)

Boiling protection

Thermal fuse

Combustion fan rpm check

Automatic frost protection

Over current - glass fuse (3 amp)

Clearances from Combustibles

* 24 inches required for serviceability

Clearances from Non-combustibles

* 24 inches required for serviceability

Min. / Max. Gas Supply Pressure

Manifold Gas Pressure (inches W.C.)

Top of heater - 6 inches

Front of heater - 6 inches *

Sides of heater - 2 inches

Top of heater - 2 inches

Front of heater - 6 inches *

Sides of heater - 1/2 inches

Natural Gas: min 5” W.C.

Propane Gas: min 8” W.C.

Natural Gas: high fire 2.9” W.C.

Propane Gas: high fire 3.7” W.C.

Back of heater - 0 inches

Bottom of heater - 12 inches

From vent pipe - 0 inches

Back of heater - 0 inches

Bottom of heater - 12 inches

From vent pipe - 0 inches

max 10.5” W.C. max 13.5” W.C.

low fire 0.70” W.C. low fire 1.06” W.C.

NOx Warranty

Meets California and Texas NOx Emission Rules

Heat exchanger: 12 years* for residential and 5 years* for commercial and hydronic applications; (10 years* if used with the Rinnai Hydronic Air Handler); all other parts 5 years*; labor 1 year; (* 3 years if used as a circulating water heater within a circulation loop, when the water heater is in series with a circulation system, all circulating water flows through the water heater and without an on-demand recirculation system). Refer to the manual for complete warranty information.

Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.

DIMENSIONS

WEIGHT: 63.9 lb (29 kg)

 

 

L

E

H

G

I

 

F

J

 

 

 

M

 

 

 

* This is the minimum dimension from the wall. The wall bracket is adjustable to allow an additional 1.57 inches (40 mm).

DIM

DESCRIPTION

in (mm)

A

Width

18.5 (470)

B

Depth

10.5 (266.9) *

C

Height - Unit

26.4 (670)

D

Height - with brackets

28.5

(723.2)

E

Hot Water Outlet - from wall

4.3 (110) *

F

Hot Water Outlet - from center

3.9 (100)

G

Cold Water Inlet - from wall

2.9 (74.6) *

H

Cold Water Inlet - from center

1.1

(27.7)

I

Gas Connection - from wall

3.9 (99) *

J

Gas Connection - from center

4.1 (103.2)

 

From base to gas connection

1.6

(40.2)

K

From base to cold connection

2.0

(50.2)

 

From base to hot connection

1.6

(41.2)

L

Condensate Dain - from wall

5.2 (132.6) *

M

Condensate Drain - from center

7.7 (195)

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us