11. Error Code Messages
Error Code Messages
Error | Content | Diagnostic Check Point |
Code |
|
|
|
|
|
00 | Power | - |
|
|
|
03 | Gas interrupted due to Tilt Switch activation | Check Tilt Switch |
|
|
|
05 | Detection of Loose Primary Filter | Check Primary Filter |
|
|
|
11 | Check Thermocouple Output | |
|
|
|
12 | Incomplete Combustion Activation | Check Thermocouple Output |
| Flame Failure |
|
|
|
|
14 | Overheat Thermistor Activation | Check Overheat Thermistor |
|
|
|
14 | Reverse Flame Safety Device | Check Reverse Flame Sensor |
|
| Switch |
|
|
|
14 | Thermal Fuse Melted | Check Thermal Fuse |
|
|
|
16 | High Temp. Cut off (10 minutes at > 40° C) | Check Room Temperature |
|
| Thermistor |
|
|
|
31 | Room Temperature Thermistor broken circuit | Check Room Temperature |
|
| Thermistor |
|
|
|
32 | Room Temperature Thermistor short circuit | Check Room Temperature |
|
| Thermistor |
|
|
|
33 | Overheat Thermistor broken circuit | Check Overheat Thermistor |
|
|
|
34 | Overheat Thermistor short circuit | Check Overheat Thermistor |
|
|
|
62 | Faulty Fan Motor rpm | Check Convection Fan Motor |
|
|
|
70 | Heater ON/OFF switch abnormal | Check Control PCB |
|
| (ON/OFF Switch) |
|
|
|
71 | Solenoids or modulating valve circuit abnormal | - |
|
|
|
72 | Thermocouple initial value abnormal | Check Thermocouple output |
|
|
|
72 | Thermocouple high | Check Thermocouple output |
| (> 48mV for 5 secs) |
|
|
|
|
73 | Communication Error between PCB & E2PROM | - |
*If the safety devices activate while either (or both) the heater and air purifier are operating, both will cease operating.
*When the unit is off, press the “override” and “∨” buttons simultaneously for at least 2.5 seconds to display the following at 2.5 second intervals in this order:
Error History (No. 1 (most recent) ~ No. 5); Estimated Combustion Time (x100H); Combustion Frequency (x100 times);
Estimated Air Purifier Operation Time (x100H); and Actual Air Purifier Operation Time (x100H).
*When the unit is off, press the “override” and “∧” and “∨” buttons simultaneously for 2.5 seconds to reset Error History and Actual Air Purifier Operation Time.
Convector 460/560PTR | - 27 - | ©Rinnai |