Rinnai RCE-560PTR manual Error Code Messages

Models: RCE-560PTR

1 71
Download 71 pages 53.36 Kb
Page 32
Image 32

11. Error Code Messages

Error Code Messages

Error

Content

Diagnostic Check Point

Code

 

 

 

 

 

00

Power re-instatement while ON/OFF switch ON

-

 

 

 

03

Gas interrupted due to Tilt Switch activation

Check Tilt Switch

 

 

 

05

Detection of Loose Primary Filter

Check Primary Filter

 

 

 

11

Mis-ignition

Check Thermocouple Output

 

 

 

12

Incomplete Combustion Activation

Check Thermocouple Output

 

Flame Failure

 

 

 

 

14

Overheat Thermistor Activation

Check Overheat Thermistor

 

 

 

14

Reverse Flame Safety Device

Check Reverse Flame Sensor

 

 

Switch

 

 

 

14

Thermal Fuse Melted

Check Thermal Fuse

 

 

 

16

High Temp. Cut off (10 minutes at > 40° C)

Check Room Temperature

 

 

Thermistor

 

 

 

31

Room Temperature Thermistor broken circuit

Check Room Temperature

 

 

Thermistor

 

 

 

32

Room Temperature Thermistor short circuit

Check Room Temperature

 

 

Thermistor

 

 

 

33

Overheat Thermistor broken circuit

Check Overheat Thermistor

 

 

 

34

Overheat Thermistor short circuit

Check Overheat Thermistor

 

 

 

62

Faulty Fan Motor rpm

Check Convection Fan Motor

 

 

 

70

Heater ON/OFF switch abnormal

Check Control PCB

 

 

(ON/OFF Switch)

 

 

 

71

Solenoids or modulating valve circuit abnormal

-

 

 

 

72

Thermocouple initial value abnormal

Check Thermocouple output

 

 

 

72

Thermocouple high cut-out

Check Thermocouple output

 

(> 48mV for 5 secs)

 

 

 

 

73

Communication Error between PCB & E2PROM

-

*If the safety devices activate while either (or both) the heater and air purifier are operating, both will cease operating.

*When the unit is off, press the “override” and “∨” buttons simultaneously for at least 2.5 seconds to display the following at 2.5 second intervals in this order:

Error History (No. 1 (most recent) ~ No. 5); Estimated Combustion Time (x100H); Combustion Frequency (x100 times);

Estimated Air Purifier Operation Time (x100H); and Actual Air Purifier Operation Time (x100H).

*When the unit is off, press the “override” and “∧” and “∨” buttons simultaneously for 2.5 seconds to reset Error History and Actual Air Purifier Operation Time.

Convector 460/560PTR

- 27 -

©Rinnai

Page 32
Image 32
Rinnai RCE-560PTR manual Error Code Messages