94

Meter type definitions

Appendices ~ Appendix E: Serial Commands

Serial command error codes

Error number

Text message

Explanation/Solution

1

Memory error

The box is out of internal memory. Power cycle the box.

2

No command found

A command was not found in the string.

3

Unknown command

A command was executed on a different device type that this box

 

response

cannot display. The command dictionary needs to be updated.

4

Not implemented

The command is not implemented.

5

Argument error

The command had an argument that was out of range.

6

Unknown command

The command is unknown to this unit.

7

Bad checksum

The binary command’s checksum is wrong.

8

Preset of macro invalid

A preset or macro failed to program because it is too large or

 

 

because its command list contained an invalid command.

10

Queue error

The internal command queue is full. Enable flow control and use

 

 

all five pins on the serial port.

11

Command too big

The binary command is too large.

12

Unit is locked

Unlock the unit with the proper password.

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Page 100
Image 100