Appendices ~ Appendix E: Serial Commands

MACRO - Macro Execution/Reporting

This command executes a specified macro or reports the last macro executed. There are 255 macros that can be specified.

Command form: DEVICE MACRO [Value]

Argument details

Name

Description

Device

0–7 or * to select all units

MACRO

Command form

Value

1-255 Value to execute user macros

Example: #45 MACRO 1 On PSR1212 unit 5 (#45), Macro (MACRO) 1 is run.

MASTER - Expansion Bus Master Mode

This command reports the mode of the unit. The mode can be Master or Slave. Command form: DEVICE MASTER [Value]

Argument details

Name

Description

Device

0–7 or * to select all units

MASTER

Command form

Value

1 = Master, 2 = Slave, Null = Current mode of the unit

Example:

#46 MASTER 2 On PSR1212 unit 6 (#46), the MASTER mode is

set to slave (2).

111

The response indicates execution of the macro, but does not indicate that

each command within the macro was executed.

MAX - Maximum Gain Setting

This command changes or reports back the maximum gain setting for an input, output or assignable processing block.

Command form: DEVICE MAX <Channel> <Group> [Value]

Argument details

Name

Description

Units

Device

0–7 or * to select all units

 

MAX

Command form

 

Channel

See Groups and Channels, page 93

 

Group

I, O, M, P, L

 

Value

-65.00 to 20.00

dB

 

Null to return the current setting

 

Example: #41 MAX 2 M 10 On PSR1212 unit 1 (#41), the maximum (MAX) relative gain setting for mic (M) channel 2 is 10dB.

This setting will affect all relative gain adjustments.

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Page 117
Image 117
ClearOne comm PSR1212 Macro Macro Execution/Reporting, Master Expansion Bus Master Mode, 111, MAX Maximum Gain Setting