Rinnai REU-VB2735WD-US manual R94LSe VB2735WD-US, Flow Table

Models: REU-VB2735WD-US

1 2
Download 2 pages 23.45 Kb
Page 1
Image 1

Type of Appliance

Rinnai Model Number

Operation

Minimum/Maximum Gas Rate (Input)

Electrical

Electrical Consumption

Ignition System

Hot Water Capacity

Temperature

Temperature (without remote)

Approved Gas Types

Installation

Energy Factor

Thermal Efficiency

Service Connections

Water Flow Control

Minimum/Maximum Water Supply Pressure

R94LSe (VB2735WD-US)

Temperature controlled, continuous flow, gas hot water system; certified for installation in manufactured (mobile) homes

REU-VB2735WD-US Forced combustion

9,900 - 199,000 BTU/h (Natural Gas)

10,300 - 199,000 BTU/h (Propane)

Appliance:

AC 120 Volts - 60 Hz

Controller:

DC 12 Volts

Normal

49 watts

Standby

2 watts

Anti-frost protection

104 watts

Direct electronic ignition

 

Minimum flow rate: 0.26 GPM

Minimum activation flow rate: 0.4 GPM

Maximum flow rate: 9.4 GPM (35° F rise)

98° - 120° F (factory default) Maximum temperature is selectable at 120° F or at 140° F; 98° - 185° F available with the MCC-91 controller for commercial and hydronic applications

120° F (factory default)

Natural or Propane (ensure unit matches gas type)

Outdoor only

 

Natural Gas: 0.82

Propane: 0.82

Natural Gas: 83%

Propane: 83%

Gas supply: 3/4 inch MNPT

Cold water inlet: 3/4 inch MNPT

Hot water outlet: 3/4 inch MNPT

 

Water flow sensor, electronic water control device and fixed by-pass 20 - 150 PSI (recommended 30-80 PSI for maximum performance)

FLOW TABLE

10.0

 

 

 

 

 

 

9.0

 

 

 

 

 

 

(gpm)

 

 

 

 

 

 

8.0

 

 

 

 

 

 

 

 

 

 

 

 

 

Rate

7.0

 

 

 

 

 

 

6.0

 

 

 

 

 

 

Flow

5.0

 

 

 

 

 

 

 

 

 

 

 

 

 

Water

4.0

 

 

 

 

 

 

3.0

 

 

 

 

 

 

Hot

2.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.0

 

 

 

 

 

 

 

0.0

 

 

 

 

 

 

 

0

25

50

75

100

125

150

 

 

 

 

∆T – Temperature Rise (°F)

 

 

 

© 2010 Rinnai Corporation

R94LSe VB SP

8/2010

Page 1