Rinnai REU-VB2735WD-US Water Temperature Control Controller, Controller Cable Safety Devices

Models: REU-VB2735WD-US

1 2
Download 2 pages 23.45 Kb
Page 2
Image 2
Water Temperature Control

Water Temperature Control

Controller

Controller Cable

Safety Devices

Clearances from Combustibles

Clearances from Non-combustibles

* 24 inches required for serviceability

Min. / Max. Gas Supply Pressure

Manifold Gas Pressure (inches W.C.) (sea level)

NOx Warranty

R94LSe (VB2735WD-US)

Simulation feed forward and feedback

MC-91-1US (included)

Deluxe controller: MC-100V-1US (optional)

Bathroom controller: BC-100V-1US (optional)

MCC-91-1US (for commercial applications)

Non-polarized two-core cable, minimum 22 AWG

Flame failure - Flame Rod

Remaining flame (OHS)

Boiling protection

Thermal fuse

Combustion fan rpm check

Automatic frost protection

Over current - glass fuse (3 amp)

• Top of heater - 12 inches

 

• Back of heater - 0 inches

Front (Panel) - 24 inches

 

• Ground / bottom - 12 inches

Front (Exhaust) - 24 inches

• Sides of heater - 6 inches

• Top of heater - 2 inches

 

• Back of heater - 0 inches

• Front (Panel) - 0 inches *

 

• Ground / bottom - 2 inches

Front (Exhaust) - 24 inches

• Sides of heater - 1/8 inch

Natural Gas:

min 5” W.C.

 

max 10.5” W.C.

Propane Gas:

min 8” W.C.

 

max 13.5” W.C.

Natural Gas:

high fire 2.8”

W.C. low fire 0.44” W.C.

Propane Gas:

high fire 5.0”

W.C.

low fire 0.93” W.C.

Meets California and Texas NOx Emission Rules

Heat exchanger: 12 years* for residential and 5 years* for commercial and hydronic applications; (10 years* if used with the Rinnai Hydronic Air Handler); all other parts 5 years*; labor 1 year; (* 3 years if used as a circulating water heater within a circulation loop, when the water heater is in series with a circulation system and all circulating water flows through the water heater)

Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.

DIMENSIONS

 

 

A

B

DIM

DESCRIPTION

R75LSe

 

 

 

 

 

 

R94LSe

WEIGHT: 51 LBS (23 KG)

 

A

Width

14 (355.6)

 

B

Depth

9.9 (251.1)

 

 

 

 

 

C

Height - Unit

22.9

(582)

 

 

 

 

 

D

Height - with brackets

25.0 (634.2)

 

 

 

C

D

E

Hot Water Outlet - from wall

3.8 (97.6)

 

 

 

F

Hot Water Outlet - from center

4.3 (110)

 

 

 

 

 

G

Cold Water Inlet - from wall

3.0 (76.6)

E

 

 

 

 

H

Cold Water Inlet - from center

1.1

(27)

 

 

 

 

I

Gas Connection - from wall

4.2 (105.6)

H

J

G

I

 

J

Gas Connection - from center

3.5

(89)

 

 

 

 

From base to gas connection

1.6

(40)

F

 

 

 

 

 

 

 

 

 

 

K

From base to cold connection

2.0

(50)

 

 

 

 

 

K

From base to hot connection

1.6

(41)

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us

Page 2
Image 2
Rinnai REU-VB2735WD-US Water Temperature Control Controller, Controller Cable Safety Devices, Clearances from Combustibles