Rinnai RV53I, RV53E installation manual Specifications, Model, RV53i, RV53e

Models: RV53I RV53E

1 60
Download 60 pages 12.68 Kb
Page 3
Image 3
Specifications

Specifications

Model

RV53i

 

RV53e

Minimum Gas Consumption Btu/h

15,000

 

20,200 (LP)

19,000 (NG)

Maximum Gas Consumption Btu/h

150,000

 

120,000

 

 

 

 

 

Hot water capacity (Min - Max) *

0.6 - 5.3 GPM (2.4 - 20.0 L/min)

 

Hot water capacity (45°F rise)

5.3 GPM (20.0 L/min)

 

4.2 GPM

(16.0 L/min)

 

 

 

 

 

 

Temperature Settings (without temperature

120º F (49º C), default or

140º F (60º C)

 

controller)

 

 

 

 

 

 

 

Temperature Controller Default Setting

104º F (40º C)

 

 

 

 

 

 

 

Maximum Temp Setting (residential)

140º F (60º C)

 

see Temperature Ranges for more information

 

 

 

 

 

Minimum Temperature Setting

98º F (37º C)

 

 

 

 

 

 

 

Weight

 

51 lb (23.0 kg)

 

34.2 lb

(15.5 kg)

Energy Factor

 

0.82

 

0.82

 

 

 

 

 

 

Noise level

 

49 dB

 

 

 

Normal

55 W

 

33 W

Electrical Consumption

 

 

 

 

 

Standby

2 W

 

 

 

Anti-frost Protection

184 W

 

74W

 

 

 

 

 

 

By-Pass Control

 

Fixed

 

 

Minimum Gas Supply

Natural Gas

5.0 inch W.C.

 

 

 

 

 

 

Pressure

Propane

8.0 inch W.C.

 

 

 

Maximum Gas Supply

Natural Gas

10.5 inch W.C.

 

 

 

 

 

 

Pressure

Propane

13.5 inch W.C.

 

 

 

Type of Appliance

 

Temperature controlled continuous flow gas hot water system.

 

 

 

 

Operation

 

With or without temperature controller, mounted in kitchen, bathroom, etc.

Approved Gas Type

 

Natural Gas or Propane - Ensure unit matches gas type supplied at the installation location.

 

 

 

 

Connections

 

Gas Supply: 3/4" MNPT, Cold Water Inlet: 3/4" MNPT, Hot Water Outlet: 3/4" MNPT

Ignition System

 

Direct Electronic Ignition

 

 

 

 

 

Electric Connections

 

Appliance: AC 120 Volts, 60Hz. Remote Control: DC 12 Volts (Digital)

Water Temperature Control

Simulation Feedforward and Feedback.

 

 

 

 

 

Water Supply Pressure

 

Minimum Water Pressure: 20 PSI (Recommended 30-80 PSI for maximum performance)

 

 

 

 

 

 

Maximum Water Supply Pressure

150 PSI

 

 

 

 

 

 

Remote Control Cable

 

Non-Polarized Two Core Cable (Minimum 22 AWG)

Energy Star Qualified

 

Yes

 

 

 

 

 

 

 

 

Certified for installation in manufactured

Yes

 

 

(mobile) homes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature.

Rinnai is continually updating and improving products. Therefore, specifications are subject to change without prior notice.

The maximum inlet gas pressure must not exceed the value specified by the manufacturer. The minimum value listed is for the purpose of input adjustment.

RV53i & RV53e Operation and Installation Manual

3

Page 3