Temperature Controller Installation

Mounting the Controller (RV53i)

Follow the procedure below to install the MC-91 or MCC-91 temperature controller.

1.

Determine a suitable location for the

 

controller.

2.

Make three holes in the wall as shown.

3.

Run the cable between the controller and the

 

Rinnai water heater or the controller and the

 

other controller.

4.

Remove the face plate from the temperature

 

controller using a screwdriver.

5.

Connect the cable to the temperature

 

controller.

6.

Mount the controller to the wall using the

 

holes drilled in step 2.

Temperature Controller

7.

Disconnect the power from the Rinnai water

 

heater.

8.

Remove the cover of the Rinnai water

 

heater.

9.

Remove the plastic cover from the PCB and

 

electrical connections.

10.

Thread the cable through the access hole at

 

the base of the unit and connect the wires to

 

the controller terminals on the right hand side

 

bottom of the PCB.

11.

Secure the controller cable using the clamp

 

provided.

12.

Replace plastic cover over PCB and then

 

replace the cover of the Rinnai water heater.

securing screw

wiring hole

securing screw

1-21/32"

3-5/16"

32

RV53i & RV53e Operation and Installation Manual

Page 32
Image 32
Rinnai RV53E, RV53I installation manual Mounting the Controller RV53i, Temperature Controller