U S I N G T H E XCARD

The crossover functions are controlled through the use of an XCard and can be set for high-pass, low-pass or full range operation. Each crossover card has two faces: one face operates Full Range, the other has arrows to indicate the edge for selecting HP (high-pass) or LP (low-pass) operation. Orient the card with the desired operating edge, indicated by the arrow, toward the socket terminals inside the amplifier. Firmly, but carefully, plug the card into the socket.

High-Pass

 

 

 

 

 

 

 

 

LP

 

 

HP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low-Pass

 

 

 

 

 

 

 

HP

LP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Full Range

FULL

The crossover point can be altered by changing the resistor value. Use the following formula to select the appropriate resistor value to be placed on the XCard.

3386

= R (in kΩ

) for .047µ f cap

The actual formula is:

fo

 

 

 

 

 

 

 

 

 

 

R =

1

 

7234 = R (in kΩ

) for .022µ f cap

2π foc

 

fo

R1

Crossover Card

R2

R1

High Pass

 

Low Pass

 

Full Range

 

FULL

R2

Where: R = ohms

fo = desired crossover frequency c = capacitor in farads

ex: .047 x 10-6for .047µ f cap

– 13 –

Page 17
Image 17