Rockford Fosgate 240X4 operation manual 160X4 S P E C I F I C A T I O N S

Models: 160X4 240X4

1 40
Download 40 pages 52.44 Kb
Page 35
Image 35
160X4 S P E C I F I C A T I O N S

160X4 S P E C I F I C A T I O N S

Continuous Power Rating (Competition Standard) – Measured at 13.8V

RMS continuous power per channel, all channels20 Watts driven into a 4load from 20-20,000Hz with

less than 0.05% Total Harmonic Distortion (THD)

RMS continuous power per channel, all channels

40

Watts

driven into a 2load from 20-20000Hz, with

 

 

less than 0.1% Total Harmonic Distortion (THD)

 

 

RMS continuous power bridged into a 4load

80

Watts

from 20-20000Hz, with less than 0.1%

 

 

Total Harmonic Distortion (THD)

 

 

Dynamic Power Rating (IHF-202 Standard) – Measured at 14.4V

 

 

2-Channel bridged into a 4load

120

Watts

per channel into a 2

load

60

Watts

per channel into a 4

load

40

Watts

Signal-to-Noise Ratio (A-weighted)

>100dB

Factory Default Crossover Point

100Hz Butterworth

Crossover Alignment

12dB/octave

Dimensions

958"W x 1258"L x 258"H

 

(24.4cm) x (32.0cm) x (6.6cm)

Damping Factor @ 4(at output connector)

>150

Bandwidth

15Hz-100kHz ± 3dB

Frequency Response

20Hz-20kHz ± 0.5dB

Slew Rate

30 V/s

IM Distortion (IHF)

<0.05%

Input Sensitivity

Variable from 150mV to 3V

 

Preset at the factory for 500mV

B+ Fuse Size (external to amplifier)

30 amp

Input Impedance

20k ohms

– 31 –

Page 35
Image 35
Rockford Fosgate 240X4 operation manual 160X4 S P E C I F I C A T I O N S