Rockford Fosgate 360.6 manual Diagnosis, Symptom, Remedy

Models: 360.6

1 68
Download 68 pages 27.56 Kb
Page 39
Image 39
Symptom

 

 

 

 

 

 

 

 

 

TROUBLE-S

 

 

 

 

 

 

 

 

 

 

 

H

 

 

 

 

 

 

 

 

 

 

 

O

Symptom

 

 

Diagnosis

 

Remedy

 

 

 

O

 

 

 

 

 

 

T

 

 

 

 

 

 

I

 

 

 

 

 

 

N

 

 

 

 

 

 

G

 

 

 

 

 

 

 

 

Speaker Output

Input gain signal for am-

Readjust input

gains

of

 

Low or Distorted

plifier is incorrectly set.

amplifier.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Source unit output too

Check system with known

 

 

 

 

 

low or source unit has

working source and repair

 

 

 

 

 

no output.

or replace original source

 

 

 

 

 

 

as needed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

XCard is missing or not

Check XCard position and

 

 

 

 

 

placed properly in cross-

repair or replace as neces-

 

 

 

 

 

over slots.

sary.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low battery voltage or

Check the alternator, bat-

 

 

 

 

 

large voltage drops to

tery, fuse, and power and

 

 

 

 

 

the amplifier under load.

ground

wiring. Repair

as

 

 

 

 

 

 

necessary.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No

Output

on

Signal Input Switches not

Check

Signal

Input

 

Channel A, Chan-

configured properly.

Switches and reconfigure

 

 

as necessary.

 

 

 

 

 

nel B, or Channel C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

XCard(s) missing or not

Check XCard position(s)

 

 

 

 

 

placed properly in cross-

and repair or replace as

 

 

 

 

 

over slot.

necessary.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low

Output

on

Signal Input Switches do

Check

Signal

Input

 

Channel C

 

 

not configure Channel C

Switches and reconfigure

 

 

 

for E-Z Bridge.

as necessary.

 

 

 

 

 

(L mono RCA input)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Amplifier Noise

Voltage spike from out-

Disconnect input signal to

 

(Turn-on pop)

 

 

put of preceding compo-

amplifier and turn ampli-

 

 

 

nent is entering amplifier

fier on and off. If noise is

 

 

 

 

 

 

 

 

 

 

through input signal.

eliminated, connect REM

 

 

 

 

 

 

lead of amplifier to source

 

 

 

 

 

 

unit with a delay turn-on

 

 

 

 

 

 

module.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage spike from remote

Use a different 12 volt

 

 

 

 

 

turn-on lead is entering

source for REM lead of

 

 

 

 

 

through REM input termi-

amplifier. (i.e., battery di-

 

 

 

 

 

nal.

rect) If noise is eliminated,

 

 

 

 

 

 

use a relay to isolate am-

 

 

 

 

 

 

plifier from noisy turn-on

 

 

 

 

 

 

output.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

– 36 –

Page 39
Image 39
Rockford Fosgate 360.6 manual Diagnosis, Symptom, Remedy