US I N G T H E XCARD
The crossover functions are controlled through the use of an XCard and can be set for
|
|
|
|
|
|
|
|
➝LP | HP➝ |
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
➝HP |
|
|
|
| ||
LP➝ |
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Full Range
FULL ↕
CUSTOMIZING T H E XCARD
The crossover point can be altered by changing all 4 resistor values. Use the following formula to select the appropriate resistor value to be placed on the XCard.
3386 | = R (in kΩ) for .047μf cap |
|
|
|
|
|
| ||
fo |
|
|
|
|
|
|
|
| |
7234 | = R (in kΩ) for .022μf cap |
|
|
|
|
|
| ||
fo |
|
|
|
|
|
|
|
| |
The actual formula is: |
|
|
|
|
|
| |||
|
|
|
|
|
| ||||
R = |
| 1 |
|
|
|
|
|
|
|
|
|
|
|
| R1 | ||||
| 2πfoc |
|
|
|
| ||||
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
Where: R = Ω
fo = desired crossover frequency c = capacitor in farads
ex: .047 x
A O
D P
V E
A R
A
N T
C I
E O
D N
Crossover Card |
| |
R2 Pass | R1 | FULLR2 |
Low Pass |
|
|
Full Range |
|
|
– 12 –