Rockford Fosgate T600-2 manual Troubleshooting, Specifications, Model- Power, T400-2

Models: T400-2 T600-2

1 52
Download 52 pages 44.57 Kb
Page 10
Image 10
SPECIFICATIONS

TROUBLESHOOTING

2.Bypass any and all electrical components between the stereo and the amplifier(s). Connect stereo directly to input of amplifier. If noise goes away the unit being bypassed is the cause of the noise.

OR

3.Remove existing ground wires for all electrical components. Reground wires to different locations. Verify that grounding location is clean, shiny metal free of paint, rust etc.

OR

4.Add secondary ground cable from negative battery terminal to the chassis metal or engine block of vehicle.

OR

5.Have alternator and battery load tested by your mechanic.Verify good working order of vehicle electrical system including distributor, spark plugs, spark plug wires, voltage regulator etc.

SPECIFICATIONS

MODEL- POWER

T400-2

T600-2

Continuous Power Rating (RMS) - Measured at 14.4 Battery Volts

4 MODEL- POWER Load Per Channel

2 T400-2 Load Per Channel

4 T600-2 Load Bridged

2 Specifications subject to change without notice Load Bridged

Dimensions: Height

Width

Length

Battery Fuse Rating (Amp) External (Not Supplied)

“A” Weighted Signal to Noise Ratio Referenced to 1 Watt into 4 ohms

“A” Weighted Signal to Noise Ratio Referenced to rated output into 4 ohms

Crossover Slope Crossover Frequency Frequency Response

Signal Voltage Adjustment Range Protection

Equalization PEQ (Punch Equalization)

Input Impedance

Operating Voltage

Balanced Inputs

CMRR (Common Mode Rejection Ratio)

Damping Factor

THD+N (Total Harmonic Distortion + Noise)

120 Watts x 2

 

200 Watts x 2

200 Watts x 2

 

300 Watts x 2

400 Watts x 1

 

600 Watts x 1

STABLE

 

STABLE

2.14" (5.42cm)

 

2.14" (5.42cm)

8.14" (20.68cm)

 

8.14" (20.68cm)

11.41" (28.97cm)

 

13.66" (34.69cm)

100A

 

150A

 

≥85 dB

≥105 dB

24dB/octave Butterworth

variable from 50Hz to 500Hz

20Hz to 20KHz ±1dB

Variable from 150mV to 5V (RCA Input)

NOMAD - Internal analog-computer output protection circuitry

limits power in case of overload, plus short protection.

Thermal switch shuts down the amplifier in case of overheating.

Variable from 0dB to +18dB @ 45Hz and/or

0dB to +12dB @ 12KHz

20K ohms

9 to 16 Volts DC

Yes

>55dB @ 1KHz

>200

< 0.1 @ 2 ohm and < 0.05 @ 4 ohm

These specifications are Amplifier Power Standard CEA-2006 Compliant

Specifications subject to change without notice

10

Page 10
Image 10
Rockford Fosgate T600-2 manual Troubleshooting, Specifications, Model- Power, T400-2