Rotel RB-06 Troubleshooting, Specifications, Protection Indicator3, Fuse Replacement, No Sound

Models: RB-06

1 42
Download 42 pages 22.85 Kb
Page 8
Image 8
Protection Indicator3

RB-06Stereo Power Amplifier

8

Protection Indicator3

The RB-06 has both thermal and over-current protection circuitry that protects the amplifier against damage in the event of extreme or faulty operating conditions. The protection circuits are independent of the audio signal and have no impact on sonic performance. Instead, the protection circuits monitor the temperature of the output devices and shut down the amplifier if temperatures exceed safe limits.

Most likely, you will never see this protection circuitry in action. However, should a faulty condition arise, the amplifier will stop play- ing and the LED indicator on the front panel will light up.

If this happens, turn the amplifier off. Let it cool down for several minutes, and attempt to identify and correct the problem that caused the protection circuitry to engage. When you turn the amplifier back on, the protection circuit will automatically reset and the indicator LED should go out.

In most cases, the protection circuitry activates because of a fault condition such as shorted speaker wires, or inadequate ventilation leading to an overheating condition. In very rare cases, highly reactive or extremely low impedance speaker loads could cause the protection circuit to engage.

If the protection circuitry triggers repeatedly and you are unable to isolate and correct the

Troubleshooting

Most difficulties in audio systems are the result of poor or wrong connections, or improper control settings. If you encounter problems, isolate the area of the difficulty, check the control settings, determine the cause of the fault and make the necessary changes. If you are unable to get sound from the RB-06, refer to the suggestions for the following conditions:

Front Panel Power Indicator Is Not Lit

No main power to the RB-06. Check the front panel power switch. Make sure that it is set to the on position. Check AC power connections at the amplifier and the AC outlet.

Specifications

Continuous Power Output

(20-20 kHz, < 0.03%, 8 ohms)

Fuse Replacement

If everything checks out correctly and you still cannot get the amplifier to turn on, the internal power fuse may have blown. If you believe this has happened, contact your authorized Rotel dealer for information on where to take your amplifier to get the fuse replaced.

No Sound

I f t h e a m p i s g e t t i n g A C p o w e r, b u t is producing no sound, check all of your connections and control settings on associated components.

70 watts/ch

faulty condition, contact your authorized Rotel dealer for assistance in troubleshooting.

Bridged Mono Power Output

180 watts

(20-20 kHz, < 0.1%, 4 ohms)

(200 watts at 1kHz)

Total Harmonic Distortion (20Hz-20kHz, 8 ohms)

< 0.03%

Intermodulation Distortion (60 Hz : 7 kHz, 4:1)

< 0.03%

Frequency Response ( ±1dB)

10Hz-100kHz

Damping Factor (20-20,000 Hz, 8 ohms)

500

 

Speaker Impedance (Normal mode)

4 ohms minimum

Signal to Noise Ratio (IHF A network)

116 dB

Input Impedance/Sensitivity

33 k Ohms/1.0 volt

Power Requirements

 

 

USA Version

120

Volts, 60 Hz

European Version

230

Volts, 50 Hz

Power Consumption

250

Watts

Dimensions (W x H x D)

437 x 72 x 342 mm

Panel Height

80 mm / 2 5/32

Weight (net)

7.5 kg, 16.54 lb.

All specifications are accurate at the time of printing.

 

 

Rotel reserves the right to make improvements without notice.

 

 