14 |
Specifications
INPUT
Voltage Range for Operation on Utility | 90V – 144V |
Nominal Voltage | 120 VAC |
Allowable Frequency for Operation on Utility | 47 – 63 Hz |
Rated Input Current | 12 Amps |
Circuit Breaker Rating | 15 Amps |
OUTPUT
Number of Outlets | 12 (all outlets are surge protected, conditioned, |
| regulated and battery backed up) |
Outlet Type | NEMA |
Rated VA Capacity | 1440 VA |
Rated Watt Capacity (continuous) | 900 Watts |
Rated Output Current | 12 Amps |
BATTERY BACKUP
Transfer Time to Battery During Blackout Battery Type/Quantity
Typical Recharge Time to 90% Capacity Battery Service
Battery Life
Battery Runtime
7ms typical, 10ms maximum
Four 12V/9A hr Sealed
User replaceable, Hot swappable
20 minutes (half load) or 7.5 minutes (full load) (Actual runtimes are determined by load, battery charge level, battery health and quantity of batteries installed)
SURGE PROTECTION
<40V | |
Data Line Protection Jacks | RJ45 |
COAX | 3 pair + splitter |
Ethernet | 1 pair, 10/100bT |
Telephone/DSL | 2 line, 4 wire with splitter |
DC Trigger | Two 3.5mm |
PHYSICAL
Unit Dimensions | 17 x 5.25 x 18.55 in. |
| 43.2 x 13 x 47.1 cm |
Unit Weight | 57 lbs / 26 kgs |
CONFORMANCE
Safety Agency Approvals | UL1778 (tested to relevant UL1449), CSA, |
| FCC Part 68 Class B |
Warranty | 2 years |
All specifications are accurate at the time of printing.
Rotel reserves the right to make improvements without notice.