Specifications

INPUT

Voltage Range for Operation on Utility

90V – 144V

Nominal Voltage

120 VAC

Allowable Frequency for Operation on Utility

47 – 63 Hz

Rated Input Current

12 Amps

Circuit Breaker Rating

15 Amps

OUTPUT

Number of Outlets

12 (all outlets are surge protected, conditioned,

 

regulated and battery backed up)

Outlet Type

NEMA 5-15R

Rated VA Capacity

1440 VA

Rated Watt Capacity (continuous)

900 Watts

Rated Output Current

12 Amps

BATTERY BACKUP

Transfer Time to Battery During Blackout Battery Type/Quantity

Typical Recharge Time to 90% Capacity Battery Service

Battery Life

Battery Runtime

7ms typical, 10ms maximum

Four 12V/9A hr Sealed Lead-Acid, Maintenance Free <8 hrs

User replaceable, Hot swappable

2-5 Years (Depending on use, environment, and temperature)

20 minutes (half load) or 7.5 minutes (full load) (Actual runtimes are determined by load, battery charge level, battery health and quantity of batteries installed)

SURGE PROTECTION

Let-Through Voltage Rating

<40V

Data Line Protection Jacks

RJ45

COAX

3 pair + splitter

Ethernet

1 pair, 10/100bT

Telephone/DSL

2 line, 4 wire with splitter

DC Trigger

Two 3.5mm mini-jack plugs (5-30V)

PHYSICAL

Unit Dimensions

17 x 5.25 x 18.55 in.

 

43.2 x 13 x 47.1 cm

Unit Weight

57 lbs / 26 kgs

CONFORMANCE

Safety Agency Approvals

UL1778 (tested to relevant UL1449), CSA,

 

FCC Part 68 Class B

Warranty

2 years

All specifications are accurate at the time of printing.

Rotel reserves the right to make improvements without notice.